5
LABOR SAVING PIPING MANIFOLDS / NEAR BOILER PIPING CONNECTIONS
LEGEND
115 & 150
205
A
Pressure Gauge
-
B
Pressure Relief Valve
30.00 psi [2.11 bar]
C
Heating return connection
3/4" [22.2mm] 1” [25.4mm]
D
Cold DHW inlet tap
1/2"
[15.9mm]
3/4" NPT
E
Gas shutoff connection
3/4" [22.2mm]
F
Cold DHW inlet tap
1/2”
[15.9mm]
na
G
DHW outlet
1/2"
[15.9mm]
3/4" NPT
H
Drain connection for condensate
13/16” [21mm]
ID Hose
3/4 NPT
I
Heating supply connection
3/4" [22.2mm] 1” [25.4mm]
J
Manifold
1-1/4"
[31.75 mm]
1-1/2”
[38.1 mm]
K
5 gpm DHW flow restrictor
(Factory installed) (205 only)
na
3/4"
[22.2mm]
MANIFOLD 205
205 COMBI
205 COMBI
A
B
H
I
E
C
K
G
D
115 & 150 COMBI
A
D
C
F
G
E
I
B
H
J
PN 240011430 REV. P [09/15/2021]