Fault Finding Solutions Sections
1.
2.
3.
Power supply 120V
1.
NO
Main terminals L and N
Check electrical supply
Connection OK at
connector x1 0
NO
Integrity of the fuse
Replace fuse
YES
NO
PCB - X1 0 connector
Check wiring
Display
illuminated
Mains terminals L & N
120V at PCB -connector x13 pump terminals Blue
to Brown (See Wiring Diagram)
NO
Replace PCB
Fan connections correct at fan and PCB
Connectors X11 & X23 See Wiring Diagram
YES
NO
120V between PCB -connector x13 pump
terminal Blue and PCB -connector x11 pump
terminal Black.
(See Wiring Diagram)
NO
Replace PCB
Make connections
Main or Display
PCB fault
120V at
Pump
NO
Check wiring
Replace
Pump
YES
YES
Is there 120V AC at fan terminals connector
X11 blue to brown. See Wiring Diagram
NO
Replace PCB
Fan jammed of faulty winding
Replace fan
FAULT SOLUTION SECTIONS
Summary of Contents for 100F
Page 33: ...33 PN 240012875 REV D 03 15 2022 MODEL 75 100 HEAT ONLY 75 100 HEAT ONLY WIRING DIAGRAM ...
Page 34: ...34 PN 240012875 REV D 03 15 2022 MODEL 125 HEAT ONLY 125 HEAT ONLY WIRING DIAGRAM ...
Page 35: ...35 PN 240012875 REV D 03 15 2022 MODEL 165 HEAT ONLY 165 HEAT ONLY WIRING DIAGRAM ...
Page 36: ...36 PN 240012875 REV D 03 15 2022 115 COMBI WIRING DIAGRAM MODEL 115 COMBI ...
Page 37: ...37 PN 240012875 REV D 03 15 2022 MODEL 150 COMBI 150 COMBI WIRING DIAGRAM ...
Page 38: ...38 PN 240012875 REV D 03 15 2022 MODEL 205 COMBI 205 COMBI WIRING DIAGRAM ...
Page 44: ...44 PN 240012875 REV D 03 15 2022 LOW WATER CUTOFF LOW WATER CUTOFF DETAIL NO NO YES ...
Page 49: ...49 PN 240012875 REV D 03 15 2022 3 FAULT SOLUTION SECTIONS ...