28141 Rev A 10-27-06
20
TABLE A-10: RECOMMENDED MINIMUM INSTALLATION CLEARANCES (INCHES)
Furnace Model
Plenum Top
Front
Rear
Side 1
Side 2
3
Flue
Pipe
Floor
Enclosure
BCL(S)-80, 90, 100, 120, 130, 145
3
24
24
6
18
9
Combustible
1
Standard
BCL-170, 190, 200, 225
3
24
24
6
18
9
Combustible
1
Standard
BFL-80, 90, 100, 120, 130, 145
3
24
24
6
18
9
Combustible
1
Standard
1
Wood Floor Only, do not install on carpeted floor, tiled floor, etc.
2
Use six 2-½ inch bricks under bottom panel if installing on wood floor.
3
Note – Purpose of the 18” side clearance is to allow a passageway from the front to the back of the furnace.
TIP: Consider greater clearances front and back for easier servicing.
TABLE A-11: GENERAL DIMENSIONS (INCHES)
Cabinet Plenum
Openings
Flue
Filter
Furnace Model
Width Depth Height Supply Gap Return Diameter
Height Type
Size
Shipping
Weight
BCL 80 – 145
22
51½
41
20½ x 18
5
/
8
2½ 20½
x
18
5
/
8
6
37¼
Permanent
20 x 25 x 1
280
BCL 170 – 225
26
49
56
24 x 22
2½
24 x 22
7
47
Permanent
20 x 25 x 1
(2)
390
BFL 80 - 145
22
51½
41
20½ x 18
5
/
8
2½ 20½
x
18
5
/
8
6
38¼
Permanent
20 x 25 x 1
250
Summary of Contents for BCL
Page 23: ...28141 Rev A 10 27 06 23 TABLE B 1 BECKETT AND RIELLO CHIMNEY VENTED WIRING DIAGRAM BCL S BFL ...
Page 24: ...28141 Rev A 10 27 06 24 TABLE B 2 BECKETT AND RIELLO DIRECT VENT WIRING DIAGRAM BCL S BFL ...
Page 29: ...29809 Rev A 10 19 2006 29 ...
Page 32: ...29809 Rev A 10 19 2006 32 ...
Page 36: ...29809 Rev A 10 19 2006 36 ...
Page 41: ...28141 Rev A 10 27 06 NOTES ...
Page 42: ...28141 Rev A 10 27 06 ...
Page 43: ...28141 Rev A 10 27 06 ...