14
Electrical wiring must conform with the latest revisions of
the National Electrical Code, ANSI/NFPA No. 70, and/or
local authority having jurisdiction.
1.
When an external electrical source is utilized, the
boiler, when installed,
MUST BE
electrically grounded
in accordance with these requirements.
2.
Install a fused disconnect switch between boiler and
meter at a convenient location.
3.
When the boiler is equipped with self-energized
controls, no outside source of electric power shall be
connected to the circuit of this system.
(See "Steam
Wiring" on next page.)
Thermostat Installation
1.
Thermostat should be installed on inside wall about
four feet above floor.
2.
NEVER
install thermostat on outside wall.
3.
Do not install thermostat where it will be affected by
drafts, hot or cold pipes, sunlight, lighting fixtures,
television, fireplaces, or chimneys.
4.
Check thermostat operation by raising and lowering
thermostat as required to start and stop burner.
5.
Instructions for final adjustment of thermostat
are packaged with thermostat (adjusting heating
anticipator, calibration, etc.).
ELECTRICAL WIRING
WARNING
Electrical shock hazard. Turn OFF electrical power
supply at service panel before making electrical
connections. Failure to do so could result in death
or serious injury.
!