2
STANDARD EQUIPMENT
:
Crated boiler, flush jacket, oil burner,
target wall/liner, safety valve, steam water level gauge, steam
pressure gauge, steam pressure control, low water cut-off, drain
valve, wiring harness, burner electric disconnect, plastic cover, 2"
supply tapping, 1½" return tapping, skim port, and primary control.
(
NOTE:
For tankless heater units, add tankless hot water coil, and
low limit control.)
DIMENSIONS
Boiler No.
Length of Flush
Jacket
Front of Jacket
to Center Line of
Flue Outlet
Flue Outlet Diameter
-A-
-B-
-C-
ESC
-3090
16⅜"
6½"
6"
ESC
-4125
20
¼
"
8½"
6"
ESC-5185
23
⅝
"
10
¼
"
7"
ESC
-6210
27½"
8
5/₁₆
"
8"
Figure #1
DIMENSIONS