32
figure 41 - 7-Day Programming Options for CAHV
Item
Setting
Values
overview
To access:
Press and hold PROGRAM and CLOCK buttons simultaneously 3 seconds; use arrow keys to select position; save selection
and exit by repeating button press.
Quick copy
— Hold FAN and PROGRAM buttons 3 seconds to copy current day’s settings to all other days.
navigating through settings:
Press PROGRAM to move to next setting or CLOCK to move to previous setting; to change values, use
UP and DOWN keys; when value is reached, move to next setting using PROGRAM or CLOCK button; values are stored on exit from
programming mode.
7-Day
Programming
(See Table 7,
Page 34 to record
settings)
Day of week
Mon, Tue, Wed,
Thu, Fri, Sat, Sun
Louver is closed when fan is off.
Period of day
Morning
Day
Evening
Night
Periods provide four time settings to initiate change in cooling/heating
setpoints.
Allow adjustments for setback (such as night setback, daytime setback
and occupied settings for residential applications).
Set hour/minute for each time as well as cooling and heating setpoints
below.
Hour
0–12 a
0–12 p
Set time to begin period.
Minute
0–59
Cooling setpoint
55–90 F
Default setpoint when set to Cooling in pre-programmed run mode.
Heating setpoint
55–90 F
Default setpoint when set to Heating in pre-programmed run mode.
Auto setpoint
55–90 F
Unit default setpoint when set to Auto in pre-programmed run mode.
(Unit auto change over between heating and cooling.)
WIRED WALL ConTRoL ConfIGURATIon