25
1"(2.54cm)
Maximum
Combustion
Air
Vent
FIGURE 6-4 Side Wall Concentric Terminal
FIGURE 6-5 Side Wall Concentric Terminal Multiple
Appliances
1" (25.4mm)
Maximum
Maintain 12"
clearance above
highest anticipated
snow level or grade
* See Note
Below
Vent
Combustion
Air
1" (25mm)
Maximum
Roof
Overhang
36"(0.9m(457mm)
(28m)) Minimum
Maintain 12"(30cm) US
(18"(46cm) Canada)
Clearance Above
Highest Anticipated
Snow Level Or Grade
12" (305mm) Minimum
*Must be less than 4" (102mm) or greater than 24"
(610mm) Horizontal distance between end bells of each air
intake to prevent
fl
ue gas recirculation.
FIGURE 6-6 Concentric Terminal Connection
Note: Securing strap must
be
fi
eld installed to prevent
movement of termination
kit in side wall
Vent
Combustion Air
1"(25.4mm)
Maximum
**See
Note
*2 or 3" (51 or 77 mm) Diameter
PVC intake/combustion air
Combustion Air
*2" (51mm) Diameter = 41" Length (1.1m)
3" (77mm) Diameter = 47" Length (1.2m)
** Note Overall length may be modi
fi
ed by cutting or extending
both combustion air and vent pipes. 12" (305mm) is minimum
allowable length and 60" (1.2m) is maximum allowable length for
this dimension.
SDR-26 PVC (D2241) only may be used for extending pipes.
Do not use Schedule 40 PVC or use couplings to extend pipes.
Dimension will change if intake/vent pipes are lengthened or
shortened.
OD 3
½
"
(89mm)
- *2"
(51mm)
kit
OD 4
½"
(114mm)
- 3"
(77mm)
kit
* Note: 2" (51mm) For use with models 050/075/100.
3" (77mm) For use with models 075/100/150/200/299
4" (101mm) For use with model 299
6 - COMBUSTION AIR AND VENT PIPING
Summary of Contents for Olsen OLSSC-299
Page 47: ...47 13 TROUBLE SHOOTING ...
Page 51: ...51 13 TROUBLE SHOOTING ...
Page 53: ...53 13 TROUBLE SHOOTING ...
Page 62: ...62 Supply Water Temperature Sensor Resistance Chart 13 TROUBLE SHOOTING ...
Page 84: ...ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com ...