Xv - boiler wirinG diaGram
COMPONENT CODING (CODE DES COMPOSANTES)
NOTE:
WIRING (CÂBLAGE)
LINE VOLTAGE BY FACTORY / LIGNE DE VOLTAGE PAR L'USINE
LOW VOLTAGE BY FACTORY / BAS VOLTAGE PAR L'USINE
LINE VOLTAGE BY INSTALLER / LIGNE DE VOLTAGE PAR L'INSTALLATEUR
LOW VOLTAGE BY INSTALLER / BAS VOLTAGE PAR L'INSTALLATEUR
240007204, REV B
ELECTRIC
AL
WIRING DIA
GR
AM (DIA
GR
AMME DE CÂBL
A
GE ÉLECTRIQUE)
TH-1 THERMOSTAT (MILLIVOLT)
TH-2 THERMOSTAT (24 VOLT)
TH-3 THERMOSTAT (LINE VOLTAGE / (VOLTAGE DE LIGNE)) TR-1 TRANSFORMER TRANSFORMATEUR (120V/24V 40VA)
TR-2 TRANSFORMER TRANSFORMATEUR (120V/24V 50VA) MGV MILLIVOLT GAS VALVE / SOUPAPE À GAZ MILLIVOLT
LGV 24 VOLT GAS VALVE / SOUPAPE À GAZ 24 VOLT
LGV-1 24 VOLT GAS VALVE / SOUPAPE À GAZ 24 VOLT
PS PRESSURE SWITCH / INTERRUPTEUR DE PRESSION
MR-PS MANUAL RESET PRESSURE SW. / REMISE EN MARCHE
MANUAL DE L'INTERRUPTEUR DE PRESSION
SD STACK DAMPER / REGISTRE DE LA CHEMINÉE
CONTROL TERMINAL / BORNE DU CONTRÔLE 1 K RELAY COIL / BOBINE DU RELAIS
1 K1 RELAY CONTACTS / CONTACTS DU RELAIS 1 K2 RELAY CONTACTS / CONTACTS DU RELAIS
LS LIMIT SWITCH / INTERRUPTEUR DE LIMITE
MS MANUAL SWITCH / INTERRUPTEUR MANUEL
CIR CIRCULATOR / CIRCULATEUR ECO ENERGY CUT-OFF / COUPE-CIRCUIT LWCO LOW WATER CUT-OFF / POUR FERMER L'EAU EWF ELECTRIC WATER FEEDER / ALIMENTEUR ÉLECTRIQUE D'EAU PG POWER GENERATOR / GÉNÉRATEUR PSC PILOT SAFETY COIL / BOBINE DE SÛRÉT DE LA VEILLEUSE WIRE CONNECTION / RACCORD DES FILS
1. SWITCHES ARE SHOWN IN POSITION TAKEN DURING HEATING CYCLE. / (LES INTERRUPTEURS SONT MONTRÉS EN POSITION DE CYCLE DE CHAUFFA
NT.)
2. IF ANY OF THE ORIGINAL WIRING SUPPLIED WITH THE BOILER IS REPLACED, IT MUST BE REPLACED WITH LIKE WIRE SIZE AND TYPE OF INS
ULATION OR EQUIVALENT.
(SI AUCUN DES FILS ORIGINAUX FOURNIS AVEC LA CHAUDÈRE EST REMPLACÉ, IL DOIT ÊTRE REMPLACÉ OAR UN AUTRE FIL DE MÊME GROSSEUR E
T DU MÊME TYPE D'ISOLATION OU L'ÉQUIVALENT.)
DISPLAY
DHW C1
DHW C2
L
N
PE
DHW PUMP 117 VAC FIELD INSTALLED
CH PUMP 117 VAC FIELD INSTALLED
CH C2
PE
N
CH C1
L
COMBUSTION FAN
117 VAC
N
PWM
FSP
+
-
PE
GAS VALVE
24 VAC
IONIZATION
N
T
OUTSIDE TEMP SENSOR
FIELD INSTALLED
OUT AIR
OUT
AIR
DHW TANK THERMOSTAT 24 VACFIELD INSTALLED
DHW T
DHW T
RETURN TEMP
SENSOR
SUPPLY TEMP
SENSOR
L2(3)
L1(1)
NC
(11)
COM
NO
(10)
RESET(7)
RESET(8)
LOW(6)
GROUND(5)
LWCO PROBE
NC
SWITCH
HOT
L1
L2
MODULA
TION BOILER CONTR
OL
CAST
SAFETY SWITCH
IGNITION
DSI
X3-1
X3-5
X3-2
X3-5
X3-3
X3-5
X3-4
X3-5
X2-10
X2-6
X2-8
X2-9
X2-7
X1-1
X1-2
X1-6
X7
X1-5
X1-3
X1-4
X1-3
X2-11
X2-12
X2-3
X2-1
X2-4
X2-2
IGNITION
TRANSFORMER
T
ROOM THERMOSTAT
FIELD INSTALLED
24V
HIGH LIMIT
THERMOSTAT
24V
L
X-10
EXT TRANS
1
2
3
4
5
6
RETURN SENSOR
CH C2
24 VOLT
DHW
T-STAT
AIR OUT 2
SUPPLY SENSOR
AIR OUT 1
X3
DHWT
DHWT
DHW C1
DHW C2
CH C1
120V HOT
NEUTRAL
EXT TRANS
T
L2
T
L1
X10
1
2
3
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
CAST SAFETY SWITCH
X2
BLOWER
MODULATION
1
2
3
4
5
1
2
3
MAIN
BLOWER
HIGH LIMIT THERMOSTAT
24V
DSI
IGNITION
TRANSFORMER
X1
X7
IONIZATION
DISPL
AY
L2(3)
LOW(6)
GROUND(5)
RESET(8)
RESET(7)
LWCO PROBE
NC
SWITCH
NO
(10)
NC
(11)
L1(1)
COM
X2-5
F
F FLAME SENSING / FLAMME SENSING
F
AIR PROVING NO SWITCH
AIR PROVING
NC SWITCH
* NOT ALL COMPONENTS LISTED ARE USED IN ALL CONTROL SYSTEMS. (LES COMPOSANTES ÉNUMÉRÉES NE SONT PAS TOUTES UTILISÉES DANS TOUS
LES SYSTÈMES DE CONTRÔLES.)
ICM 491
120 VOLT POWER
SUPPLY (USE COPPER
CONDUCTORS ONLY)
NC
NO
COM
L1
L2
L2
WHT
RED
BLK
ICM 491
NC
NO
COM
L1
L2
L2
WHT
RED
BLK
27