ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
36
Operating conditions
Everything at a glance
Power indication proportional to the
continuous output indicated in
120 % – 150 % for 10 seconds
150 % – 200 % for 2 seconds
Switching time UPS (TMI Series)
<16 ms
AC voltage
230 V
AC voltage fluctuation: max . 10%
Frequency: 50 Hz ± 1%
Waveform
Modified sine wave
Battery types
Wet, AGM, GEL, Li-Ion (only with BMS)
Efficiency range*
system voltage
Efficiency
12 V
85 % – 89 %
24 V
86 % – 90 %
48 V
87 % – 91 %
* Actual efficiencies depend on the type of consumer and load .
For example, the inverter typically has the highest efficiency at a load of approx . 70 % .
Idle current consumption MI-/TMI-series
Model MI/TMI
12 V
24 V
48 V
30
approx . 0,30 A
approx . 0,15 A
approx . 0,08 A
60
approx . 0,45 A
approx . 0,22 A
approx . 0,11 A
100
approx . 0,50 A
approx . 0,25 A
approx . 0,13 A
150
approx . 0,65 A
approx . 0,33 A
approx . 0,17 A
200
approx . 0,70 A
approx . 0,35 A
approx . 0,18 A