ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
37
Model MI/TMI
12 V
24 V
48 V
250
approx . 0,85 A
approx . 0,43 A
approx . 0,22 A
300
approx . 0,95 A
approx . 0,48 A
approx . 0,24 A
Recommended surrounding conditions
Operating temperature
-15 °C bis 40 °C
Storage temperature
-40 °C bis 85 °C
Relative humidity
20 % ~ 90 %
☝
Please note!
Please mind the starting current!
Keep in mind that inductive devices (for example power drills or refrigerators etc .) often
need a 3–10 times higher power at the beginning than indicated on the descriptive
type plate . The maximum power of this short period should not surpass the maximum
power of the inverter .
☝
Please note!
Listen to the acoustic signal!
In case of overload an acoustic signal will sound . If the needed power is not reduced to
the maximal continuous output, the inverter will shut down automatically .
☝
Please note!
Output losses because of heat
An ambient temperature over 40°C (for ex . due to heat at the installation site or direct
sunlight) can lower the specified output and efficiency .