ECTIVE
®
POWER INVERTER – MI-/TMI-SERIES
]
44
☝
Please note!
Exclusion of liability
Damages caused by polarity reversal and short circuits are excluded from liability .
Self error correction
Symptom
Possible reason
Solution
Inverter does
not work
1 . connection to
consumers cut off
2 . battery voltage
to low
1 . check battery connection
2 . check charging status
acoustic signal
sounds
and red LED
flashes
possible undervolt-
age (see table)
1 . check charging status of battery, charge if
necessary
2 . check compatibility of battery cable, use
higher cross section if necessary
3 . check if conductive parts (cables, pole
terminals, lugs) are damaged .
acoustic signal
sounds
and red LED
flashes
total undervoltage
(see table)
1 . check charging status of battery, charge if
necessary
2 . check compatibility of battery cable, use
higher cross section if necessary
3 . check if conductive parts (cables, pole
terminals, lugs) are damaged
red LED
flashes
input voltage too
high (see table)
1 . check voltage
2 . check charging voltage of battery charger
3 . check if there are unwanted voltage
sources
red LED
flashes
inverter overheated
1 . check ventilation, if damaged, call support
2 . check if ventilations slits are free
3 . check if ambient air is cool enough
4 . reduce power