DIGITAL ECU TUNER 3 – User Manual
Modification of frequency signals
Digital Ecu Tuner 3 has a wide range of configurations, which allow to modify and generate the frequency signals:
1) Modification of the frequency signal using Fuel Table,
2) Generating the frequency signal using Fuel Table, used for the MAF to MAP conversion.
3) Clamping of the upper and lower value of the input frequency, used for removing electronic road speed
governor (modification of the VSS signal).
4) Generating the output signal for the electronic tachometer, based on the current engine speed.
1. Modification of the frequency signals using the Fuel Table.
To modify frequency from the flow meter or frequency map sensors, connect signal to the
Frequency In
input
.
In
most cases it will be necessary to connect the pull-up resistor, as most of the sensors are
open collector
type.
Depending on the frequency range of t sensor, it is possible
to use one of two modes of the signal’s value change:
linear
or
nonlinear
. For a linear mode, frequency change
is linear, proportional to the product of the map’s value and
the value of the
Base Unit.
Also, value of the output signal
is limited in the range defined by the
Freq. Min and
Freq.Max
. units. This mode is used for sensors with
frequency range not higher than 500Hz.
FreqOut
= MapValue * Base Unit
If (
FreqOut
< FreqMin)
FreqOut
= FreqMin
If (
FreqOut
> FreqMax)
FreqOut
= FreqMax
Page 32
www.ecumaster.com
ECU
Frequency In (9)
Frequency Out (7)
Pullup (8)
DET 3
Frequency
MAF/MAP