balance value from touch screen by press UP and DOWN button. After adjustment, the data show on screen is

3.3

Section 5

Installation and Operation

E-DNS06 Ionizing Air Snake can neutralize charges and eliminate dust inaccessible trouble spot hard to reach
area. It is a hand free flexible ionizing nozzle. The height and angle of nozzle can easily be adjusted.

Put the device at the working position you need. You may screw it if it is needed. The Air Snake comes with
a quick release air connector; simply connect it to a standard 8mm air hose. To connect tubing to quick connect
fitting: Cut end of plastic tubing square and clean. Push against the collar with thumbnail. While holding collar
in, push tubing into the fitting until it bottoms out completely.
Please ensure that the H

T

Cable securing gland is firmly tightened. This insures a good earth connection.

Connect the power cord to its corresponding inlet on the base of the ionizer.
Turn the unit on with the red button.

Section 6 Maintenance

Keep the air snake clean and free from oil, water and particle contamination.Use air drying and cleansing filter
regulator with 5 micron filtration. Ensure that all connections, pipe work and filter regulators will allow
minimum 15 CFM of air flow. Clean and purge filter regulators periodically and check for contamination in the
air delivery pipe. From time to time remove the front nozzle cap by unscrewing anti-clockwise, disconnect from
H.V. electric supply before removing the nozzle cap. Clean around the electrode pin with a pipe cleaner or
cylindrical soft brass brush. Ensure the plastic inner lining is free from gray or black carbonized residue. The
point of the electrode pin can be cleaned by pushing a pencil end eraser on to the electrode pin and rotating.
Blow out the loose debris and re-fit the nozzle cap before re-connecting the high voltage supply and operating.

The ion balance voltage and static elimination time of the ion air curtain are in compliance with the ESD

standard, and the static elimination time is measured

Section 7 Warranty and Service

1. The warranty period is one year. We will repair the products free of charge due to the quality problems

caused by the product's own parts, materials and process problems within one year from the date of sale.

2. After the maintenance period

After the maintenance period of the products sold by us, we are still responsible for repairing the labor of
the products to protect the our customers

interest.

www.esd-conductive.com

Summary of Contents for E-AID202

Page 1: ...tive com Address 151 Houjie Dadao Houjie Town Dongguan City China Post code 523961 E mail sales01 esd conductive com INSTRUCTION E AID202 Smart Ionizing System with LCD Touch Screen Auto Clean Real Time Ion Balance monitoring w w w e s d c o n d u c t i v e c o m ...

Page 2: ...ound terminal is connected to a grounded cable and the terminal knob tightened Failure to do so may result in electrical shock Do not position the equipment such that it is difficult to disconnect the plug When doing electrode needle maintenance be sure to disconnect the AC plug from the outlet Do not connect or disconnect the power plug with wet hands as doing so puts you at risk of electrical sh...

Page 3: ...arge air volume range from one to ten classes air control technology using large air volume DC fan eliminating static electricity quickly and fast Unbalanced alarm prompt technology alarm threshold voltage can be set manually When the ion balance voltage is out of balance and exceeds the set threshold voltage the unit will automatically alarm This machine is equipped with automatic cleaning functi...

Page 4: ...nd press Ent to end the setting NOTE the setting ranges from 0 99V 2 Ion Balance Voltage Calibration Strongly recommend professional technician to do this setting First of all hand over the unit and keep distance about 300mm or desired distance but within 900mm to make sure proper static elimination performance from the static charged plate meter Make test and adjust the ion Environmental Temperat...

Page 5: ...tamination Use air drying and cleansing filter regulator with 5 micron filtration Ensure that all connections pipe work and filter regulators will allow minimum 15 CFM of air flow Clean and purge filter regulators periodically and check for contamination in the air delivery pipe From time to time remove the front nozzle cap by unscrewing anti clockwise disconnect from H V electric supply before re...

Reviews: