background image

Information for DRY use Vacuum cleaners 

24.3

WARNING

Read the instruction manual before using the machine.

Operators shall be adequately instructed on the use of these machines.

As with all electrical equipment, care and attention must be exercised at all times during use, in 

addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe 

operation.

Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard 

could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.

This machine is for DRY USE only and must not be stored outside or used in wet conditions.

The machine shall be disconnected from the mains by removing the plug from the supply socket during 

cleaning or maintenance and when  replacing parts or converting the machine to another function.

This machine is not to be used by children or persons with reduced physical, sensory or mental 

capabilities, or lack of experience or knowledge. 

Children should be supervised to ensure they do not play with the machine 

This machine is not a toy.

Ensure that the fi ltration system fi tted to the machine is suitable for the material being collected.

CAUTION

This machine is for use indoors only.

This machine should be stored indoors only. 

NOTES

This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 Stability and Mechanical 

Hazards.
This machine is intended for commercial use, for example in hotels, schools, hospitals, 

factories, shops, rental businesses and offi  ces for other than normal housekeeping purposes.

DO

• 

Keep your machine clean.

• 

Keep hoses and tubes clear.

• 

Replace any worn or damaged parts immediately.

• 

Regularly examine the power cord. If damage is found such as cracking or ageing the power cord 

must be replaced by a qualifi ed person using the correct Numatic original part.

• 

Change 908082 H Class Filter Unit with the correct Numatic approved replacement part.

• 

Only use the brushes provided with the machine.  The use of other brushes may impair safety.

• 

Only replace the power cord with the correct Numatic approved replacement part.

DO NOT

• 

Unreel the cable with one pull or pull on the cable to unplug the machine from the power supply.

• 

Use to suck up hot ashes or lighted cigarette ends.

• 

Use steam cleaners or pressure washers to clean the machine or use in the rain.

• 

Immerse in water for cleaning.

• 

Attempt machine maintenance or cleaning unless the power supply plug has been removed from the 

supply outlet.

• 

Under any circumstances place foreign objects including (but not limited to) air fresheners, air 

freshener capsules or scented beads of any type into the top fi lter of the machine. Doing so can be 

dangerous and risk damage to the machine and may invalidate the machine warranty.

Summary of Contents for Numatic HZC 390L-2

Page 1: ...L 2 HZC 390S 2 Original Instructions Original Instructions CAUTION Read instructions before using the machine CAUTION Read instructions before using the machine HZC 390S 2 HZC 390L 2 1000W Kit AA16 Au...

Page 2: ...Kit AA16 2 1 3 Assembly...

Page 3: ...5 4 6 Air Diffuser Hose...

Page 4: ...Using your machine I 0 Start Netzschalter D marrage Start Ligar Avvio Encender Otwarty Moving your Machine...

Page 5: ...lter Unit from the drum 4 Place the Filter Unit and Hose Assembly inside an impervious plastic bag and seal the bag Dispose of the plastic bag depending on contamination in an appropriate manner Note...

Page 6: ...will illuminate and flash when the air speed in the suction hose falls below 20m s This indicates that the filter cartridge requires changing Low Flow Warning Light Cause Solution Suction hose blocked...

Page 7: ...3 2 1 6 5 4 9 8 7 10 11 Changing Replacing Cable...

Page 8: ...Dust Allergens Protection Hi Viz Jacket Caution Floor Sign NOTE A risk assessment should be conducted to determine which PPE should be worn 1 Company Name Address 2 Model 3 Voltage Alternating Current...

Page 9: ...d be stored indoors only NOTES This product complies with the requirements of clause 20 of IEC EN 60335 2 69 Stability and Mechanical Hazards This machine is intended for commercial use for example in...

Page 10: ...dicates that the cartridge filter must be changed This machine is not suitable for connection with dust generating machines The cartridge filter must be undamaged and in correct position before this m...

Page 11: ...re safety critical only replace with the genuine Numatic spare parts For user servicing the machine must be dismantled cleaned and serviced as far as is reasonably practicable without causing risk to...

Page 12: ...Tie Replacement parts Schematic Diagram Data 1 2 3 4 5 6 Drum Size Cleaning Range Weight Ready to work Sound Pressure Protection Class Dimensions 1 2 3 4 5 6 HZC 390S 2 HZC 390L 2 13 L 26 8 m 12 2 kg...

Page 13: ...warranty claims must be processed through either the Dealer from whom the equipment was originally purchased or another authorised Edgar Edmondson Pty Ltd Australia dealer The Dealer will co operate...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...International Limited Chard Somerset TA20 2GB ENGLAND Tel 01460 68600 www numatic co uk Specification subject to change without prior notice www numatic co uk Numatic International Limited Distribute...

Reviews: