sky is visible.
EDW-310
is in an inner place
Wait for the target to come out
Battery is low
Recharge the unit and the GPS will start working.
8 SMS Command List
(Remarks: ****** is user’s password, and the default password is 000000)
Description
Command
Remarks
Get current location
W******,000
Get current location of
EDW-310
Change user’s password
W******,001,######
****** is old password
###### is new password
Set interval for automatic
timed report
W******,002,XXX
XXX is the interval in minute. If
XXX=000 it will stop tracking
Set preset phone number
for SOS button
W******,003,F,P,T
F=0, to turn off this function;
F=1, to send SMS;
As SOS button is linked to IN1, P=1.
T: Preset phone number. Max 16 digits
Set low power alert
When
EDW-310
voltage
is lower than the preset
value, it will send one low
power alert to the SOS
preset number.
W******,004,X
X (voltage preset value)
=0 , to turn off this function
=1, <3.3V send SMS alert
=2 , <3.4V send SMS alert
=3 , <3.5V send SMS alert (default )
=4 , <3.6V send SMS alert
=5 , <3.7V send SMS alert
Set over speed alert
When
EDW-310
speeds higher
than the preset value, it
will send an SMS to the
SOS preset number.
W******,005,XX
XX (the preset value of speed)
=00 , to turn off this function
=[01, 20] (unit: 10Km/h)
For example, W000000,005,08, it will
sent alert when it is over 80Km/h
Set Geo-fence alert
When the
EDW-310
moves
out of preset scope, it will
send one Geo-fence SMS
to the SOS preset number.
W******,006,XX
XX ( preset distance to original place )
=00, close
=01, 30m
=02, 50m
=03, 100m
=04, 200m
=05, 300m
=06, 500m
=07, 1000m
=08, 2000m
- 13 -