SIMS GO
53
1.
Automatic detection indication.
Once an indication has been scanned on a plate, it gets added
into the indication list with an MFLA / unknown status represented by a yellow rectangle. The
indication status can be changed to either accepted (long press) or rejected (short press) using
the software dropdown option or the dedicated FloormapX tablet button.
Figure 49: Tablet button to change indication status
For accepted indications, the following indication details are editable:
•
Surface.
•
Method.
•
Comment.
•
EPL value and Est. Remain.
For rejected indications, or indication that remain as MFLA / unknown status, their details
remain greyed out and non-editable.
NOTE
For all automatically detected indications, location and dimension values cannot be edited.
2.
Manual indication.
These can be placed anywhere in the plate view by using the add indication
tool. When adding a manual indication its status is only set to accepted and greyed out, all other
fields are editable. Once the values are entered the indication can be added by applying them in
the indication list or to cancel out of the add indication menu. Once in the full indications list,
manual indication values will remain editable.
4.5
Calibration
In the calibration page the correct calibration must be selected for plate scanning. The options are
to create a calibration, to load an existing one from the inspection or to import a calibration from
another inspection.
Figure 50: Calibration page
NOTE
When the text Create, Load or Import Calibration is displayed then no calibration is selected.
Please create or load a calibration to continue.
Summary of Contents for Floormap X
Page 1: ...User s Manual Floormap X MFL Array Tank Floor Inspection Solution...
Page 10: ...10 Chapter 1 Precautions and conventions...
Page 16: ...General Precautions and Conventions 16 1 5 EU Declaration of Conformity...
Page 19: ...19 Chapter 2 FloormapX System Overview...
Page 35: ...35 Chapter 3 Inspection Preparation Setup and Operation...
Page 43: ...43 Chapter 4 SIMS GO Data Acquisition Software...
Page 69: ...69 Chapter 5 SIMS PRO...