SIMS GO
63
Figure 80: Start scan position - track origin
NOTE
A dead zone of 174mm (6.85in) accounts for the area at the start of any scan not accessible
to the FloormapX MFL sensor head due to its physical position within the system.
•
Resume: this allows a new scan to continue from the previous scan on the same track but
include an offset gap between the scans due to obstacles. A track can be resumed as many
times as required. When selected the offset value is calculated by measuring the distance
between the laser line.
Figure 81: Start scan position - resume
IMPORTANT
Mark the laser line on the floor before repositioning the scanner to the next scan.
NOTE
As an alternative to the resume a new scan could be continued by selecting Track Origin and
entering an offset measurement from the start of the plate.
•
Plate Ref.: an coordinate offset value based on the (x,y) location from plate reference to the
left hand side of the scanning bridge. This is particularly useful for annular plates where the
track origin may be unknown.
Figure 82: Start scan position - plate ref