SIMS GO
64
Viewing Plates
The navigation bar at the top of the plate view allows you to cycle through created plates for further
analysis.
Allows to choose whether to load inner plates or annular plates in the
view.
•
Inner plates consist of rectangular and sketch plates.
•
Annular plates consist of straight bottom and curved bottom
plates.
Loads the previous or next created plate in the view.
Data Views
In the navigation bar at the top of plate view the data views for a plate can be switched between the
available options:
Top & Bottom: show top and bottom indications from the scans.
Top: show only the top indications from the scans.
Bottom: show only the bottom indications from the scans.
STARS: show data collected from the STARS sensor.
MFLA: show data collected from the MFL array sensor.
Color Palette
In the navigation bar at the top of the plate view the color palette for the selected data views can be
selected. Different palettes are available depending on the data views:
For Top & Bottom, Top and Bottom channels:
•
Floormap.
•
Thermo.
•
Jet.
•
Color blind.
For STARS channel:
•
Gray.
•
Jet.
For MFLA channel:
•
Thermo.
•
Thermo up.
•
Jet.