Print Date 08/04/14 Page 34 of 34 S79005-00MA-05
When the E2026 AUTO – MUTE – START switch is set to MUTE or START (i.e. manual control), the
display shows the actual switch setting and the manual setting of high/low power (‘Manual=’). The
latter can only be done by an internal link (i.e. this setting of high/low power cannot be done from the
front panel). In this mode, the switch mute/start selection can only be over-ridden by the safety
interlock opening and muting the Transmitter directly (the first part of the display then showing
‘Manual=I-Lock’). The automatic settings are displayed as ‘Auto=’ and can be set as described in the
previous paragraph.
When the E2026 AUTO – MUTE – START switch is set to AUTO, the display shows the automatic
settings in operation. As before, the mute/start selection can be over-ridden by the safety interlock
opening and muting the Transmitter directly (the first part of the display then showing ‘I-Lock’).
However, auto operation also allows the internal auto mute/start setting to be over-ridden by the rear
panel ‘Mute Transmitter Input’ (see section 2.2.8) the first part of the display then showing ‘(ext)Mute’.
The order of priority is thus ‘I-Lock’ then ‘(ext)Mute’ then ‘Start/Mute’ as selected internally. When ‘I-
Lock’ or ‘(ext)Mute’ are operative, the START/MUTE soft-keys are disabled, being shown as ‘(x)’,
though this selection can still be made using remote control.
Similarly with the E2026 AUTO – MUTE – START switch set to AUTO, the internal high/low power
setting can be over-ridden by the rear panel ‘Select Low Power Input’ (see section 2.2.8) the second
part of the display showing ‘Low(ext)’. The order of priority is thus ‘Low(ext)’ then ‘High/Low’ as
selected internally. When ‘Low(ext)’ is operative, the HIGH/LOW soft-keys are disabled, being shown
as ‘(x)’, though this selection can again still be made using remote control.
It should be noted that auto mode has to be selected by the E2024 AUTO – MUTE – START switch to
enable low power to be selected remotely or via the front panel. The only manual mode provision for
selecting low power is via an internal link, which then over-rides all other auto settings that might be
made.
To display the output power again, press [MAIN] as previously described.
--oOo—