QUESTIONS AND ANSWERS
If the heater cycles ON/OFF without heating:
Please note: This is a smart heater that monitors the room temperature and
produces heat only when needed.
You can set the desired room temperature with the heater in
ECO
mode. (The
factory default setting is 68 °F.) For an example of how the heater works, let’s
say you set the temperature for 70 °F, the heater will run on HIGH until the
room temperature reaches 70°F. The heater will switch to run on LOW for 10
minutes. And then the unit will turn to NAP mode for saving energy, the heater
will turn off when the room temperature is equal or greater than 69°F, the
heater will run on HIGH power again when the room temperature drops to 68°F.
(
Note
: The heater remains on STANDBY as long as you do not POWER OFF).
As the heater remains on STANDBY, it will read the room temperature every 5
minutes by running the heating 40 seconds and fan 60 seconds. During this
process, the fan also blows out the residual heat from inside the chamber to
ensure an accurate temperature reading of the room. If the room temperature
is at 72 °F (or higher), the heater will remain on STANDBY. It will repeat this
sensing cycle
, reading the room temperature, every 5 minutes. However, if the
room temperature drops 2 degrees
lower
than the set temperature, the heating
function will turn the heater ON and the fan will blow warm air.
If the heater cycles but doesn’t produce heat for hours:
If the temperature is set
lower
than room temperature, the heater will perform
only the sensing cycle
and the heater will not turn on in the heating function. To
have the heater turn on,
always
set the desired temperature
higher
(2°+) than
the room temperature.
Summary of Contents for A5955