Cellular service
6.1
Parameters definition
6.1.1
AT#PHYTIMEOUT
6.1.1.1
Definition
This parameter is used by the CellGO3G to automatically abort the cellular connection when a long
period elapses without activity. “Without activity” is defined as a period when no data is sent or
received by the CellGO3G over Internet (Cellular interface) or over the serial port. This timer prevents
the CellGO3G from being tied up if for any reason, some part of the system becomes stuck.
6.1.1.2
Setting / Getting
Set value: AT#PHYTIMEOUT=<Value>
Get value: AT#PHYTIMEOUT? or AT#VCELLULAR, AT#VALL
6.1.1.3
Legal values
Integer between 0 and 255 inclusive. This timer is set in minutes.
When set to 0, the CellGO3G never automatically aborts the connection.
6.1.1.4
Default value
15 (fifteen)
6.1.2
AT#APNPW
6.1.2.1
Definition
Access Point Name password parameter is given, with Access Point Name server and password, by the
Cellular operator to provide cellular data network access.
6.1.2.2
Setting / Getting
Set value: AT#APNPW=<Value>
Get value: AT#APNPW? or AT#VCELLULAR, AT#VALL
6.1.2.3
Legal values
Alphanumeric ASCII text string up to 50 characters.
6.1.2.4
Default value
Empty
6.1.3
AT#APNSERV
6.1.3.1
Definition
Access Point Name server parameter is given, with Access Point Name username and password, by the
Cellular operator to provide cellular data network access.
6.1.3.2
Setting / Getting
Summary of Contents for CellGO3G