50
3.
Current ramp:
output current ramp of PPS20 can be set with this option. It
can be set from 1…
3000mA/s for any mode of operation.
Turn rotary encoder or use arrow buttons
▲
or
▼
to select
Current ramp
tab; press
ENTER
button or rotary knob to edit. Press
ENTER
button or
rotary knob again to confirm the settings.
NOTE:
If Ramps are activated, all of the ramps works simultaneously
–
it is
independent from Constant Power, Voltage or Current operation.
NOTE:
Sometimes there is a problem to start the plasma with some gases, target
materials and vacuum conditions. Turn the Ramp option off and try again if any
problem with plasma exist.
4.3.6
SOFTWARE
M
ENU
Turn rotary encoder or use arrow buttons
▲
or
▼
to select
SOFTWARE
tab; press
ENTER
button rotary knob to edit
–
Fig 4.3.17
Fig.4.3.17
Most common information are displayed here. Software version is part of it
–
Fig.4.3.18
Fig.4.3.18
NOTE:
Firmware can be upgrad
ed by the user at any time. Refer to the “PPS20
Firmware Upgrade manual” –