– 1 –
Quick Start Guide
Attach the Brackets
1.
Attach each of the front- and rear-post brackets to the switch
using four of the included bracket screws.
2.
Use the screws and cage/clip nuts supplied with the rack to
secure the switch in the rack.
Adjust Rear-Post Bracket Ears
1.
Lock the position of the rear-post bracket ears using the included
position-locking screws.
You can adjust the rear-post bracket ears to fit different rack
depths from 56 cm to 75 cm.
Ground the Switch
1.
Ensure the rack is properly grounded and in compliance with
ETSI ETS 300 253. Verify that there is a good electrical
connection to the grounding point on the rack (no paint or
isolating surface treatment).
2.
Attach the grounding wire (#14 AWG) to the grounding point
on the switch rear panel. Then connect the other end of the wire
to rack ground.
Warning:
For a safe and reliable installation, use only
the accessories and screws provided with the AS7726-
32X. Use of other accessories and screws could result in
damage to the unit. Any damages incurred by using
unapproved accessories are not covered by the warranty.
Avertissement:
Pour une installation sûre et fiable,
utilisez uniquement les accessoires et les vis fournies avec
le AS7726-32X. L’utilisation d’autres accessoires et vis
pourrait endommager l’appareil. Les dommages causés
par l’utilisation d’accessoires non approuvés ne sont pas
couverts par la garantie.
Caution:
The switch includes plug-in power supply (PSU)
and fan tray modules that are installed into its chassis. All
installed modules must have a matching airflow direction.
That is, if the installed power modules have a front-to-back
(F2B) airflow direction, all the installed fan tray modules
must also have a F2B airflow direction.
Attention:
Le commutateur comprend des modules
d’alimentation et de bac de ventilateurs installés sur son
châssis. Tous les modules installés doivent avoir une
direction de circulation d’air correspondante. C’est-à-dire
que tous les modules doivent avoir la même direction de
circulation d’air : avant vers arrière (F2B), ou arrière vers
avant (B2F).
Note:
The switch has the Open Network Install
Environment (ONIE) software installer pre-loaded on the
switch, but no switch software image. Information about
compatible switch software can be found at
www.edge-core.com
.
1
1
1
2
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack,
while the other person secures it using the rack screws.
Attention:
Deux personnes sont nécessaires pour installer
un commutateur dans un bâti : La première personne va
positionner le commutateur dans le bâti, la seconde va le
fixer avec des vis de montage.
2
1
3
1
2
E092019-CS-R03
150200001963A
www.edge-core.com
32-Port 100G Top-of-Rack Switch
AS7726-32X
1.
32-Port 100G Top-of-Rack Switch AS7726-32X
2.
Rack mounting kit—2 front-post brackets, 2 rear-post
brackets, 20 screws, and 2 ear-locking screws
3.
Power cord (included with AC PSUs only)
4.
Ground wire (included with DC PSUs only)
5.
Console cable—RJ-45 to DB-9
6.
DC power connector (included with 48 VDC PSU only)
7.
Documentation—
Quick Start Guide
(this document) and
Safety and Regulatory Information
1
Package Contents
2
3
4
5
7
6