Mount the SD-WAN Edge CPE
1.
Attach the brackets to the SD-WAN Edge CPE.
2.
Use the screws and cage nuts supplied with the rack to secure
the SD-WAN Edge CPE in the rack.
Ground the SD-WAN Edge CPE
1.
Ensure the rack on which the SD-WAN Edge CPE is to be
mounted is properly grounded and in compliance with
international and local standards. Verify that there is a good
electrical connection to the grounding point on the rack. (no
paint or isolating surface treatment)
2.
Attach a lug (not provided) to a #18 AWG minimum grounding
wire (not provided), and connect it to the grounding point on the
device’s rear panel. Then connect the other end of the wire to
rack ground.
Connect Power
1.
Plug the power cord into a 100-240 VAC, 50-60 Hz AC power
source.
2.
Insert the other end of the power cord directly into the AC input
socket on the back of the device.
Caution:
Risk of explosion if battery is replaced by an
incorrect type. Dispose of used batteries according to the
manufacturer’s instructions.
Attention:
Risque d’explosion si la batterie est remplacée par
un type incorrect. Éliminez les piles usagées conformément aux
instructions.
1
2
1
2
1
Caution:
The earth connection must not be removed unless
all supply connections have been disconnected.
Attention:
Le raccordement à la terre ne doit pas être retiré
sauf si toutes les connexions d’alimentation ont été
débranchées.
Caution:
The device must be installed in a restricted-access
location. It should have a separate protective earthing terminal
on the chassis that must be permanently connected to earth to
adequately ground the chassis and protect the operator from
electrical hazards.
Attention:
L'appareil doit être installé dans un emplacement
à accès restreint. Il doit comporter une borne
de terre de
protection distincte sur le châssis, qui doit être connectée en
permanence à la terre pour assurer une mise à la terre
adéquate du châssis et protéger l'opérateur des risques
électriques.
Caution:
Use the AC power cord supplied with the
device
.
For International use, you may need to change the AC line
cord. You must use line cord sets that have been approved for
the socket type in your country.
Attention:
Utilisez le cordon d’alimentation secteur fourni
avec l’appareil. Pour une utilisation internationale, vous devrez
peut-être changer le cordon d’alimentation secteur. Vous devez
utiliser des jeux de cordons d’alimentation qui ont été
approuvés pour le type de prise dans votre pays.
3
2
1
E072022-CS-R01
SD-WAN Edge CPE
SDW100
1.
SDW100 SD-WAN Edge CPE
2.
Rack Mounting Kit—2 brackets and 8 screws
3.
Power cord—either Japan, US, Continental Europe or UK
4.
Console cable—RJ-45 to DB-9
5.
Documentation—
Quick Start Guide
(this document)
2
5
1
4
3
Package Contents
www.edge-core.com