background image

–  

1

  –

Quick Start Guide

Mount the SD-WAN Edge CPE

1.

Attach the brackets to the SD-WAN Edge CPE.

2.

Use the screws and cage nuts supplied with the rack to secure 
the SD-WAN Edge CPE in the rack. 

Ground the SD-WAN Edge CPE

1.

Ensure the rack on which the SD-WAN Edge CPE is to be 
mounted is properly grounded and in compliance with 
international and local standards. Verify that there is a good 
electrical connection to the grounding point on the rack. (no 
paint or isolating surface treatment)

2.

Attach a lug (not provided) to a #18 AWG minimum grounding 
wire (not provided), and connect it to the grounding point on the 

device’s rear panel. Then connect the other end of the wire to 

rack ground.

Connect Power

1.

Plug the power cord into a 100-240 VAC, 50-60 Hz AC power 
source.

2.

Insert the other end of the power cord directly into the AC input 
socket on the back of the device.

Caution:

 Risk of explosion if battery is replaced by an 

incorrect type. Dispose of used batteries according to the 

manufacturer’s instructions.

Attention:

 Risque d’explosion si la batterie est remplacée par 

un type incorrect. Éliminez les piles usagées conformément aux 

instructions.

1

2

1

2

1

Caution:

 The earth connection must not be removed unless 

all supply connections have been disconnected.

Attention:

 Le raccordement à la terre ne doit pas être retiré 

sauf si toutes les connexions d’alimentation ont été 

débranchées.

Caution:

 The device must be installed in a restricted-access 

location. It should have a separate protective earthing terminal 

on the chassis that must be permanently connected to earth to 

adequately ground the chassis and protect the operator from 

electrical hazards.

Attention:

 L'appareil doit être installé dans un emplacement 

à accès restreint. Il doit comporter une borne

 de terre de 

protection distincte sur le châssis, qui doit être connectée en 

permanence à la terre pour assurer une mise à la terre 

adéquate du châssis et protéger l'opérateur des risques 

électriques.

Caution:

 Use the AC power cord supplied with the 

device

For International use, you may need to change the AC line 

cord. You must use line cord sets that have been approved for 

the socket type in your country.

Attention:

 Utilisez le cordon d’alimentation secteur fourni 

avec l’appareil. Pour une utilisation internationale, vous devrez 

peut-être changer le cordon d’alimentation secteur. Vous devez 

utiliser des jeux de cordons d’alimentation qui ont été 

approuvés pour le type de prise dans votre pays.

3

2

1

E072022-CS-R01

SD-WAN Edge CPE

SDW100

1.

SDW100 SD-WAN Edge CPE

2.

Rack Mounting Kit—2 brackets and 8 screws 

3.

Power cord—either Japan, US, Continental Europe or UK

4.

Console cable—RJ-45 to DB-9

5.

Documentation—

Quick Start Guide

 (this document)

2

5

1

4

3

Package Contents

www.edge-core.com

Summary of Contents for SDW100

Page 1: ...accordement à la terre ne doit pas être retiré sauf si toutes les connexions d alimentation ont été débranchées Caution The device must be installed in a restricted access location It should have a separate protective earthing terminal on the chassis that must be permanently connected to earth to adequately ground the chassis and protect the operator from electrical hazards Attention L appareil do...

Page 2: ...one of the following methods DHCP Automatic configuration Static Manually set the IP address subnet mask default gateway and DNS servers PPPoE Set the PPPoE username and password 4 Click Save to confirm the configuration and enable the SD WAN Edge CPE to communicate with the Barrista controller Hardware Specifications 4 1 1 5 3 1 2 6 Chassis Size WxDxH 42 6 x 27 0 x 4 4 cm 16 8 x 10 6 x 1 7 in Wei...

Page 3: ...btained from www edge core com support download Japan VCCI Class A Laser Safety Warning Fiber Optic Port Safety Avertissment Ports pour fibres optiques sécurité sur le plan optique Warnhinweis Faseroptikanschlüsse Optische Sicherheit Battery Safety Power Cord Safety Please read the following safety information carefully before installing the device Warning Installation and removal of the unit must...

Page 4: ... Geräts und leicht zugänglich sein Die Stromversorgung des Geräts kann nur durch Herausziehen des Gerätenetzkabels aus der Netzsteckdose unterbrochen werden Der Betrieb dieses Geräts erfolgt unter den SELV Bedingungen Sicherheitskleinstspannung gemäß IEC 60950 Diese Bedingungen sind nur gegeben wenn auch die an das Gerät angeschlossenen Geräte unter SELV Bedingungen betrieben werden 电源线安全 安装交换机前 请...

Page 5: ...n Warning When selecting a fiber SFP SFP device considering safety please make sure that it can function at a temperature that is not less than the recommended maximum operational temperature of the product You must also use an approved Laser Class 1 SFP SFP transceiver Warning This equipment is not suitable for use in location where children are likely to be present Caution Wear an anti static wr...

Page 6: ... 產品開機一段時間之後 散熱片及部份 IC 表面可能會發熱 發 燙 請勿用手觸摸 並請檢查系統是否散熱不良 在安裝或移除周邊產品時請先關閉電源 電源供應器如果發生損壞 切勿自行修理 請交由授權經銷商處 理 產品的機殼 鐵片大部份都經過防割傷處理 但是您仍必須注意 避免被某些細部鐵片尖端及邊緣割傷 拆裝機殼時最好能夠戴上 手套 當你有一陣子不使用產品時 休假或是颱風天 請關閉電源之後 將電源線拔掉 警告 此产品不含任何用户可维修的部件 警告 本机的安装和拆卸必须由专业人士来完成 警告 在将此设备连接到电源插座时 将三插片电源插头 上的接地导线连接到有效的接地线路 以防止电气危险 警告 此交换机使用激光器通过光纤线缆发射信号 这些 激光器符合 1 类激光产品的要求 在正常使用情况下对眼 睛无害 但是 切勿在电源开启状态下直接注视发射端口 警告 在选择光纤 SFP SFP 设备时 为安全起见 请...

Page 7: ...Ӱ Ӱ 榾嶏篪 1PXFS DPSE Ӱ Ӱ Ӱ Ӱ Ӱ 溍葏ꧠ蔷 Crystal Ӱ Ӱ Ӱ Ӱ Ӱ 冓留 Diode Ӱ Ӱ Ӱ Ӱ Ӱ 榾ꡢ Resistor Ӱ Ӱ Ӱ Ӱ Ӱ 儗辑劲 䩺 SJ T 11364 2014 氳鈺㲋籁 ն Ӱ 辑炐塝鼨 榫氳䢦僗 眷免乢 塝熨僗夽䡝僗㲺擻顏氳 ꄈ GB T 26572 2011 鈺㲋氳 金姳ն Ӱ Indicates the toxic or hazardous substance content of the part at the homogenous material level is lower than the threshold defined by Requirements for Concentration Limits for Toxic or hazardous Substances in Electronic Inf...

Reviews: