1

Mount the Device

Rackmount the Device

1.

Attach the brackets to the device.

2.

Use the screws and cage nuts supplied with the rack to secure 
the device in the rack.

Desktop Mount the Device

1.

The device can be installed on a desktop or shelf using the 
included adhesive rubber foot pads.

Ground the Device

1.

Ensure the rack is properly grounded and in compliance with 
international and local standards. Verify that there is a good 
electrical connection to the grounding point on the rack (no 
paint or isolating surface treatment).

2.

Attach the grounding wire (#18 AWG) to the grounding point 
on the device rear panel. Then connect the other end of the wire 
to rack ground.

Connect Power

1.

Install one AC PSU in the device.

2.

Connect an external AC power source to the PSU.

Verify Device is Powered On

1.

Verify the device is powered on by checking the Power LED.

When operating normally, the Power LED should be on green.

Warning:

 This equipment is not suitable for use in 

locations where children are likely to be present.

Avertissement: 

Cet équipement ne peut pas être utilisé 

dans des endroits où des enfants sont susceptibles d’être 

présents.

1

1

2

1

2

1

2

Caution:

 The earth connection must not be removed unless 

all supply connections have been disconnected.

Attention:

 Le raccordement à la terre ne doit pas être retiré 

sauf si toutes les connexions d’alimentation ont été 

débranchées.

3

1

2

4

1

E072022-CS-R01

SD-WAN Edge CPE

SDW101

1.

SD-WAN Edge CPE SDW101

2.

Rackmount Kit—2 brackets and 8 screws

3.

Four adhesive foot pads

4.

Power Cord—either Japan, US, Continental Europe or UK 

5.

Console Cable—RJ-45 to DB-9

Package Contents

2

4

5

3

www.edge-core.com

Summary of Contents for SDW101

Page 1: ...vice 2 Connect an external AC power source to the PSU Verify Device is Powered On 1 Verify the device is powered on by checking the Power LED When operating normally the Power LED should be on green Warning This equipment is not suitable for use in locations where children are likely to be present Avertissement Cet équipement ne peut pas être utilisé dans des endroits où des enfants sont susceptib...

Page 2: ...firm the configuration and enable the SD WAN Edge CPE to communicate with the Barrista controller Hardware Specifications 5 1 2 6 Form Factor 1 RU rackmount Dimensions W x D x H 442 x 298 3 x 43 6 mm 17 4 x 11 74 x 1 72 in Weight 4 43 kg 9 77 lb with two installed PSUs CPUs CPU Intel Atom Processor C3758 SoC 14nm 2 2 GHz Support 8 cores Memory Sockets 2x260pin DDR4 SODIMM slots Type 2 x 8GB DDR4 2...

Page 3: ... 2013 ED 4 0 Power frequency magnetic field immunity test according to IEC 61000 4 8 2009 ED 2 0 Voltage dips short interruptions and voltage variations immunity test according to IEC 61000 4 11 2020 ED 3 0 LVD EN 62368 1 2014 A11 2017 The Declaration of Conformity DoC can be obtained from www edge core com support download Japan VCCI Class A Laser Safety Warning Fiber Optic Port Safety Avertissme...

Page 4: ... T par le biais d un transformateur d isolement à rapport 1 1 avec un point secondaire de connexion portant l appellation Neutre et avec raccordement direct à la terre masse Bitte unbedingt vor dem Einbauen des Switches die folgenden Sicherheitsanweisungen durchlesen Warnung Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Das Gerät sollte nicht an eine ungeerdete We...

Page 5: ...smission lorsque ce dernier est sous tension Avertissement Lorsque vous utilisez un dispositif fibre de type SFP SFP en ce qui concerne la sécurité assurez vous qu il puisse fonctionner à une température inférieure à la température maximale de fonctionnement recommandée du produit Utilisez également un émetteur récepteur laser SFP SFP de classe 1 agrée Attention La manipulation de cet équipement r...

Reviews: