background image

 

Introduction 

 

Thank you for purchasing this EdgeStar portable air conditioner. We are glad you chose us. We 
believe that your purchase of this product opens a relationship between you and EdgeStar.  We 
will provide the customer support needed to nurture that relationship.  
 
This manual contains important information regarding the proper installation, use and 
maintenance of your portable air conditioner. Following this manual will ensure that your product 
will work at its peak performance and efficiency. 
 
Please save the original product packaging in case you need to safely transport your portable air 
conditioner.  
 
 

For Your Records: 

Please write down the model number and serial number below for future 

reference. Both numbers are located on the ratings label on the back of your 
unit and are needed to obtain warranty service. You may also want to staple 
your receipt to this manual as it is the proof of your purchase, and is also 
needed for service under your warranty. 

 

Model Number:  

__________________________________ 

 
Serial Number:   

__________________________________ 

 
Date of Purchase: 

__________________________________ 

 
To better serve you, please do the following before contacting customer service: 
 

 

If you received a damaged product, immediately contact the dealer that sold you the 
product. 

 

 

Read and follow this instruction manual carefully to help you install, use and maintain 
your portable air conditioner. 

 

 

Read the troubleshooting section of this manual as it will help you diagnose and solve 
common issues.  

 

 

Visit us on the web at 

http://www.edgestar.com

 for product guides, additional 

troubleshooting resources and up-to-date information.  If you need service, our friendly 
customer service representatives are available via email at 

service@edgestar.com

 or 

by telephone at 

1 (866) 319-5473

 
 
 

4

 

Summary of Contents for AP420HS

Page 1: ...AP420HS Portable Air Conditioner Owner s Manual This owner s manual provides instructions on safe installation use and maintenance Please read it carefully and save it for reference ...

Page 2: ...n ON OFF switch 2 Do not use the unit in extremely humid or wet environments 3 Do not wet the housing or control panel 4 Do not pull the unit by the cord 5 Always turn the unit off and unplug it from the socket when cleaning 6 Unplug the unit if it is not going to be used for a long period of time 7 Do not operate the unit with a damaged plug or a loose socket 8 Use only the correct power supply w...

Page 3: ...lation 6 Exhaust Hose Installation 7 Operation Using the Control Panel 9 Using the Remote Control 11 Maintenance Water Drainage 12 Extending the Drain Tube 13 Cleaning the Unit 14 Preparation for Storage 14 Optimizing Performance 15 Troubleshooting 16 Specifications 17 EdgeStar Limited Warranty Information 18 3 ...

Page 4: ...ded to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number __________________________________ Serial Number __________________________________ Date of Purchase __________________________________ To better serve you please do the following before contacting customer servic...

Page 5: ...ust air outlet 9 Water stopper drainage point Accessories 10 Exhaust hose 11 Window kit part 2 for filling the open window space 12 Window kit part 1 used to connect the exhaust hose and filling the remaining open window space 13 Oval adapter for insertion onto hose and into window kit 14 Remote control 15 Active carbon filter 16 Drain tube for continuous drainage 5 ...

Page 6: ... pre filter frame 3 Remove the activated carbon filter from its plastic bag 4 Place the activated carbon filter into the pre filter frame 5 Secure the filter by reassembling the pleated panel to the pre filter frame 6 Install the pre filter frame to the unit Note Replace the activated carbon filter every 2 3 months or as needed Pleated panel Pre filter frame 6 ...

Page 7: ...e window across so that the kit is held securely You may need to adjust the size of the window kit and secure it with screws This technique may also be used for sash windows Note Take care to secure your window against intruders 2 Thread the exhaust hose to the Exhaust air outlet of the portable air conditioner 3 Thread the oval adapter to the exhaust hose 4 Attach the adapter to the window kit 7 ...

Page 8: ... to work less efficiently Improper setup may cause the unit to overheat and shut off Figs 6 7 show the correct position The hose may be extended from 11 to 59 For maximum efficiency use the shortest length possible FIG 6 FIG 7 FIG 8 WARNING The length of the exhaust hose is specially designed according to the specification of this product Longer hoses are not recommended FIG 9 8 ...

Page 9: ... Temperature up button Turning the Unit On or Off Press the POWER button and the unit will start in auto mode If the ambient temperature is Higher than 73o F the unit will operate in cool mode Higher than 68o F but below or equal to 73o F the unit will operate in fan mode Below 68o F the unit will operate in heating mode An indicator will display next to the corresponding mode NOTE The display win...

Page 10: ...to Automatically Shut Off the Unit While the machine is running press the TIMER button to set the number of hours you want to wait for the machine to shut off automatically You are able to set the time between 1 to 24 hours by continuing to press the TIMER button The timer indicator will light up When the time set has elapsed the machine will turn off automatically The display window will show the...

Page 11: ... change between auto cooling heating or fan modes 7 Fan Speed Button Used to set the fan speed 8 Up Button Used to increase the temperature NOTICE 1 To prolong the compressor s life please wait at least 3 minutes before turning the unit back on after shutting it off 2 The cooling system will shut off if the ambient temperature is lower than the set one The fan however keeps working on the set leve...

Page 12: ...ray for example underneath the drain hole 3 Remove the drain cap rubber plug from the drain hole and allow the water to drain out 4 When the container is almost full replace the rubber plug in the drain hole and empty the water tray 5 Repeat steps 2 through 4 until the unit is emptied 6 Replace the rubber plug and tighten the drain cap firmly 7 Switch on the unit the Water Full indicator will stop...

Page 13: ...evel 2 Flashing Comp Water indicator will not function in this mode of drainage 3 This unit will not shut off when an external drain pan tray is filled 4 If you want to extend the water tube you can connect it with another tube Diameter 0 71 5 When the room humidity is over 85 we recommend continuous drainage Drain tube Original drain tube FIG 15 Extended drain tube Outer Diameter 0 71 13 ...

Page 14: ...se dust and dirt then rinse thoroughly under warm running water that is no hotter than 104o F Dry thoroughly before replacing Note The activated carbon filter is not washable replace it as needed Contact EdgeStar at 1 866 319 5473 or via email at service edgestar com for replacement filters Warning Never operate the unit without the filters Follow the instructions below to prepare your product for...

Page 15: ... room before you arrive You may want to operate the unit all day if you live in a warmer climate 7 Minimize the heat sources direct sunlight computers servers people etc in the room 8 Close all windows and doors 9 Use the unit in a contained room For example a room with four walls and a roof instead of a partitioned studio or warehouse 10 Make sure the unit is on a level surface 11 Minimize the am...

Page 16: ...rs etc 5 Run the unit before it is needed For example run the unit in the morning before the area gets hot and continue to run the unit all day long in order to maintain a low temperature 6 Use more than one unit to cool the area or use a larger unit Remove the exhaust hose and run the unit for 5 minutes Compare the air temperature between the exhaust and the front If the exhaust is warmer than th...

Page 17: ... 1230W 9 2 A Maximum Dehumidifying Capacity 55 pints day Refrigerant R22 15 2OZ Fan speeds 2 High and Low Timer 1 24 hours Net Weight 64 lbs Dimensions 29 1 3 x 14 1 3 x 15 1 2 HxWxD Notice Electrical products should not be disposed with household waste Please check with your local authorities to locate an appropriate recycling facility 17 ...

Page 18: ...on free of charge on a mail in basis to EdgeStar s authorized repair facility during the first 90 days from the date of original purchase All defective product components covered by this warranty will be repaired or replaced at EdgeStar s option on a mail in basis to EdgeStar s authorized repair facility during the time period beginning on the 91st day from the date of original purchase and ending...

Page 19: ...For product guides additional troubleshooting resources and up to date information visit us on the web at http www edgestar com EdgeStar Products Box 81336 Austin TX 78708 1336 Toll Free 1 866 319 5473 ...

Reviews: