background image

Installation Instructions 

 

You can use the EdgeStar dehumidifier to create a comfortable 
environment and prevent damage caused by moisture to books or 

valuables in areas such as basements or home libraries. Follow the 

instructions below to unpack and set up your unit.  
 

1.

 

Carefully unpack the dehumidifier from its box and packaging 
material, and remove any adhesive tape holding the water 

bucket and filter in place. You may want to save the box for 

storing and transporting the unit. Let the unit sit upright for at least 
24 hours before powering it on to allow the compressor’s fluids to 

settle. 

2.

 

Place the dehumidifier on a level floor or surface that is strong 
enough to support the unit with a full bucket of water in a room 

where the ambient temperature will not drop below 41°F, and 

away from any heat sources such as direct sunlight, heaters, 
radiators, dryers, etc.  

 

Allow at least 10 inches of space all around the unit and at least 20 inches 
of space above the unit.

 

 

If you have multiple power outlets in the room, choose one that is near the 
dehumidifier and that will be able to provide adequate power to the unit. 

See the power requirements listed in the product label located on the 

side, or on the back of your dehumidifier. 
 

3.

 

Close all windows and doors. To be most effective, use the 

dehumidifier in a contained room as opposed to a partitioned 
studio or warehouse type space.  

4.

 

To activate the unit and ensure the warning switches are 

engaged, remove the water bucket and reinstall it; otherwise, the 
unit may not work properly.   

5.

 

Plug the unit in to a grounded outlet. (Read the Safety Information 

section.) 

 

Note

:  

 

Dehumidifiers working 
in a basement will 
have little or no effect 
on adjacent enclosed 
rooms such as closets, 
unless there is enough 
circulation of air in and 
out of the enclosed 
area. 

 

The unit is designed to 
work in environments 

with temperatures 
between 41°F and 95°F 

Caution

:  

This unit is for freestanding, 
indoor use only and will not 
operate correctly if used 
outdoors or if built in under a 
counter or cabinet.   

Summary of Contents for DEP500WP

Page 1: ...Dehumidifier Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com Model DEP500WP...

Page 2: ...ds emits smells or smoke comes out of it and contact customer service Do not remove any part of the casing unless instructed by an authorized technician You should never attempt to repair the unit you...

Page 3: ...N SPEEDS 5 SETTING THE HUMIDITY LEVEL 5 LCD DISPLAY 6 Temperature and Timer Display 6 Humidity Level Display 6 Error Codes 6 WATER FULL LIGHT 6 ADDITIONAL NOTES ABOUT THE DEHUMIDIFIER S BEHAVIOR 6 DRA...

Page 4: ...Your Records Please write down the model number and serial number below for future reference Both numbers are located on the ratings label on the back of your unit and are needed to obtain warranty s...

Page 5: ...EdgeStar Portable Dehumidifier 2 Parts Identification Back View Front View Water Level Indicator Water Bucket Air Intake Control Panel Handle Exhaust Gravity Drain Outlet Casters Pump Drain Outlet...

Page 6: ...the unit and at least 20 inches of space above the unit If you have multiple power outlets in the room choose one that is near the dehumidifier and that will be able to provide adequate power to the...

Page 7: ...ter bucket is full and must be emptied Timer Lights up to indicate that the unit is in timer mode High Speed Lights up to indicate the fan is on the high setting Normal Speed Lights up to indicate the...

Page 8: ...mately 10 seconds before reverting back to displaying the current temperature 5 To cancel or turn off the timer setting adjust the increments by using the Increase and Decrease buttons until 0 hours i...

Page 9: ...ambient temperature is suitable for the unit 41 F 95 F If the ambient temperature is suitable please contact customer service HI Temperature too high error Current room temperature is above 122 F Make...

Page 10: ...ed properly 3 Place the other end of the drain hose in a floor drain or other suitable drainage port 4 Operate unit in normal manner 5 To remove pump drain line press the release button located direct...

Page 11: ...the continuous gravity drain you will need to supply a suitable drain hose You may use a standard garden hose with a connector fitting 1 Locate the gravity drain hose port found on the back of the un...

Page 12: ...ater bucket and then remove the pre filter as shown below 2 Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt then rinse thoroughly under lukewarm running water below 104 F...

Page 13: ...varies and is dependent on the ambient temperature and relative humidity of the operating environment The auto defrost indicator located on the control panel will light up when the auto defrost featu...

Page 14: ...y dehumidifier is not functioning at all Unit is not receiving power Make sure the unit is plugged in Insufficient power Move the unit to another outlet Check your circuit breaker Refer to the rating...

Page 15: ...ve a faulty control panel Restart the unit and if issue persists contact customer service Unit has an E1 Error Temperature sensor error Restart the unit and if issue persists contact customer service...

Page 16: ...Model DEP500WP Voltage Frequency AC 115V 60Hz Power Consumption 540W Operating Current 4 7A Water Bucket Capacity 8 5 Liters 2 25 Gallons Dehumidifying Capacity 80F RH60 50 Pints Day Refrigerant R410...

Page 17: ...ruct in proper usage of the product Damages or operating problems resulting from misuse abuse operation outside environmental specifications uses contrary to instructions provided in the owner s manua...

Page 18: ...service edgestar com Register your product download owner s manuals access additional troubleshooting resources and obtain more information on other great EdgeStar products on the web at http www edge...

Reviews: