PROBLEM
SOLUTION
Pulsation Flow - Pump cycles on and off
Restricted pump delivery. Check dischrage lines, fittings and valves for
undersizing or clogging. Clean screens in faucets. Some filters or purifiers
are highly restrictive. Filters/purifiers with high pressure drop may require
a separate line and/or the installation of an accumulator tank in the
system.
Failure to Prime - Motor operates, but no pump discharge
Restricted intake or dscharge line
Air leak in intake line
Punctured pump diaphragm
Debris under flapper valves
Crack in pump housing
Pump fails to turn off after all fixtures are closed
Empty water tank
Punctured pump diaphragm
Discharge line leak
Defective pressure switch
Insufficient voltage to pump
Debris under flapper valves
Low flow and pressure
Air leak at pump intake
Accumulation of debris inside pump and plumbing
Worn pump bearing (excessive noise)
Punctured pump diaphragm
Defective motor
Motor fails to turn on
Loose wiring connection
Pump circuit has no power
Blown fuse/thermal protector tripped
Pressure switch failure
Defective motor
U.S.A
UK
CANADA
JAPAN
GERMANY
ITALY
Jabsco
Jabsco
Fluid Products Canada
NHK Jabsco Company Ltd.
Jabsco GmbH
Jabsco Marine Italia
Cape Ann Industrial Park
Bingley Road, Hoddesdon
55 Royal Road
3-21-10, Shin-Yokohama
Oststrasse 28
Via Tommaseo, 6
Gloucester, MA 01930
Hertfordshire EN11 OBU
Guelph, Ontario N1H 1T1
Kohoku-Ku, Yokohama, 222
22840 Norderstedt
20059 Vimercate, Milano
Tel: +1 978 281 0440
Tel: +44 (0) 1992 450145
Tel: 519 821 1900
Tel: +45 475 8906
Tel: +49 (40) 53 53 730
Tel: +39 039 685 2323
Fax: +1 978 283 2619
Fax: +44 (0) 1992 467132
Fax: 519 821 2569
Fax: +45 475 8908
Fax: +49 (40) 53 53 7311
Fax: +39 039 666 307
THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT
TO THE JABSCO THREE-YEAR LIMITED WARRANTY,
WHICH IS AVAILABLE FOR YOUR INSPECTION UPON
REQUEST.
Copyright 2005, ITT Industries
Printed in U.S.A.
All Rights Reserved
Form: 43000-1810
Rev 05/2005B
Sanitizing
WARNING:
BEFORE SERVICING PUMP, TURN OFF PUMP AND DRAIN WATER FROM SYSTEM!!
TROUBLESHOOTING
www.jabsco.com
Potable water systems require periodic maintenance to deliver a consistent flow of fresh water. Depending on use and the
environment the system is subjected to, sanitizing is recommended prior to storing and before using the water system after a period
of storage. Systems with new components, or ones that have been subjected to contamination, should also be disinfected as
follows:
(
NOTE: The sanitizing procedure is in conformance with the approved procedures of the US Public Health
Service.)
1. Use the following methods to determine the amount of common household bleach needed to sanitize the tank:
A. Multiply “gallons of tank capacity” by 0.13; the result is the ounces of bleach needed to sanitize the tank
(30 gallons X .13 = 3.9 oz bleach).
B. Use the number of liters of tank capacity to determine the number of mililiters of bleach needed to sanitize the tank
(120 liters of tank capacity = 120 mililiters of bleach).
2. Mix into solution the proper amount of bleach within a container of water
3. Pour the solution (water/bleach) into the tank and fill the tank with potable water.
4. Open all faucets (hot and cold) allowing the water to run until the distinct door of chlorine is detected.
5. The standard solution must have four (4) hours of contact time to disinfect completly. Doubling the solution concentration allows
for contact time of one (1) hour.
6. When the contact time is completed, drain the tank. Refill with potable water and purge the plumbing of all sanitizing solution.
Summary of Contents for 268 Center Console
Page 1: ...268CC 268 Center Console OWNER ASSISTANCE MANUAL Revised 2014...
Page 32: ...31 Appendix 268CC...
Page 33: ...34...
Page 34: ...35 Hydraulic Steering System...
Page 35: ...36...
Page 36: ...37...
Page 37: ...38...
Page 38: ...39...
Page 39: ...40...
Page 40: ...41...
Page 112: ......
Page 129: ......
Page 146: ...8 Rotation of Ports 1 2 3 4 5 6 7 1 Rotation of Pump Head 2 3 4 5...
Page 186: ...38 A B 50 mm C 20 mm...