background image

time the machine is used. Failure to do that may cre-

ate a flood around the machine.

•  Do not leave dirty water inside the tank, pump or hos-

es after each operation of the machine. Run clean wa-

ter through the pump. Rinse the tank and completely 

drain the vacuum and discharge hoses. Run vacuum 

motor for three minutes minimum so that the inside 

of the vacuum turbine is free of residual moisture.

•  Monitor vacuum system to prevent flooding.

GROUNDING INSTRUCTIONS:

This piece of equipment must be grounded. Should an 

electrical malfunction occur, grounding provides a path 

of least resistance for electrical current, reducing the risk 

of electric shock. This piece of equipment is furnished 

with a cord that has a grounding conductor and ground-

ing plug. The grounded plug must only be plugged 

into an appropriate outlet that is properly installed and 

grounded in accordance with all local codes and ordi-

nances.

WARNING:

Connecting the equipment to an improperly grounded 

outlet can result in an increased risk of electric shock. A 

qualified electrician should be consulted if you are un-

sure that the outlet is properly grounded. Do not modify 

the plug provided with the equipment. If it will not fit 

the outlet, have a proper outlet installed by a qualified 

electrician.

This appliance is designed for use on a 120-volt circuit. 

The grounding plug provided looks like the plug illus-

trated in Figure 1. Replace the power cord if the ground-

ing pin is damaged or broken.

Extension cords connected to this machine should be 

12 gauge, three-wire cords with three-prong plugs and 

outlets.  DO NOT use extension cords more than 25 feet 

(7.6 m) long.

 

DAILY MAINTENANCE: 

The FLOODBUSTER FB50 is engineered and built to 

require minimum maintenance. But like any machine, 

it does require some care to keep it in optimum work-

ing condition. Careful attention to these maintenance 

instructions will give you maximum operating perfor-

mance and life expectancy of the machine. 

CAUTION: Disconnect the power cord from the out-

let before doing any clean up or maintenance on the 

machine

1.  Keep the equipment and accessories, inside and out, 

clean and dry including lid, filter strainer, waste tank, 

hoses.

2.  Vacuum motor: It is very important that the vacuum 

motor is internally free of moisture when not used. 

Run the vacuum motor with the lid and hose off for 

3 minutes after every operation. 

3.  Pump motor: Periodically hose off the surface of the 

pump so that no debris may remain on the surface 

and opening of the pump. Such debris may cause 
pump damage in time. 

Servicing:

In the event that your equipment requires service, please 

contact EDIC at:

 800-338-3342 

or email info@edic-usa.com 

Do not attempt repairs yourself. EDIC will assist you in 

locating an indepedent service contractor. 

 

Storage:

1.  Store in a clean, dry location. 

2.  Store with the lid off the machine

Purchase record: 

Fill in the blanks and keep for future reference.

Model #:

Serial #:

Distributor name:

Distributor contact:

4

Figure 1

Summary of Contents for FLOODBUSTER FB50

Page 1: ...sing Michigan 48906 Fax 517 484 9836 Email CustomerService Michco com Website www Michco Com Order Parts online at www Michco Com Directly to Parts Service By Email CustomerService Michco com By Fax 5...

Page 2: ...w FLOODBUSTER FB50 PROFESSIONAL FLOOD EXTRACTOR OWNER S OPERATOR S MANUAL PROUDLY DESIGNED AND MANUFACTURED BY WWW EDIC USA COM Edition 1 9 21 16 Intended for commercial use only...

Page 3: ...TENANCE INCLUDED ACCESSORIES FB50 MACHINE OVERVIEW SPECIFICATIONS SETTING UP THE MACHINE OPERATION OF THE MACHINE AFTER OPERATING THE MACHINE TROUBLESHOOTING WIRING DIAGRAM FB5O TANK BREAKDOWN FB50 BA...

Page 4: ...lity of the end user Failure to comply with the following warning instructions will void the warranty Make sure the machine is plugged into an electrical outlet with the same voltage and frequency rat...

Page 5: ...ed in Figure 1 Replace the power cord if the ground ing pin is damaged or broken Extension cords connected to this machine should be 12 gauge three wire cords with three prong plugs and outlets DO NOT...

Page 6: ...5 INCLUDED ACCESSORIES 1 2 3 4 5 1 J00616 25 1 5 X 25 VACUUM HOSE 2 J14056A 1 5 X 25 DISCHARGE HOSE 3 K11192 SQUEEGEE HEAD 4 K007001 SCALLOP TOOL 5 D03386 1 TWO PIECE WAND...

Page 7: ...ip ment 5 LID LOCKING LATCH Used to lock or release the tank lid 6 TANK Houses pump and holds waste water 4 6 7 HOSE SUPPORT Supports a hose when hose is wrapped around machine Has hook openings for b...

Page 8: ...on the machine 13 on page 6 3 Position the end of the discharge hose in a safe drain age location Check local laws and regulations for proper waste water disposal 4 Make sure the debris basket with ga...

Page 9: ...the vacuum motor 2 Turn off the switches and unplug the power cord from the machine power inlet and also from the wall power outlet 3 Dump the water remaining in the tank after opera tion 4 Rinse the...

Page 10: ...9...

Page 11: ...46 52 12 60 11 13 48 47 45 44 34 38 9 7 10 1 6 8 54 43 28 31 2 14 39 41 39 40 24 23 53 19 49 50 20 26 25 21 55 30 22 32 33 29 16 17 37 15 57 58 56 3 5 4 51 14 26 41 7 38 7 38 37 63 62 67 61 65 66 66 2...

Page 12: ...BOW 1 17 K00665 1 1 1 2 HOSE ADAPTER 1 18 D14032 L BRACKET 1 19 D13609 SWITCH PANEL REV 04 1 20 D13877 VENT COVER 1 21 B02211 1 ROCKER SWITCH 2 22 E13982 SWITCH PLATE PAD 1 23 F13983 SWITCH PLATE PLUG...

Page 13: ...54 C14053 1 4 20 X 1 SCREW FH SS 2 55 K13905 5 16 NYLON PLUG 2 56 C00295 1 10 X 3 4 SHEET METAL SCREW SS 2 57 H02574 PUMP SWITCH LABEL 1 58 H02576 VACUUM SWITCH LABEL 1 59 C02268 10 32 X 3 8 SCREW FL...

Page 14: ...13 1 25 23 5 24 8 6 19 16 10 20 17 15 14 9 7 2 18 3 21 22 12 11 13 4 13 FB50 BASE 7 15 2016 26 19 16 27 29 28...

Page 15: ...8 16 C00233 1 1 4 ID FLAT WASHER SS 8 17 C00313 1 4 20 X 3 4 HEX BOLT 6 18 C00311 8 32 X 3 8 SCREW 4 19 C00254 1 4 SPLIT LOCKWASHER 8 20 C10737 8 32 X 5 8 TRUSS HEAD SCREW SS 4 21 C02320 8 32 NYLON L...

Page 16: ...PANEL GASKET 1 3 D13608 INTAKE PANEL 1 4 K13920 1 1 2 HOSE BARB 1 5 E11128 DRAIN VALVE GASKET 1 6 C00271 1 1 2 JAM NUT 1 7 D14054 1 1 2 ID EXTENSION TUBE 1 8 J00618 1 1 1 2 WIRE REINFORCED HOSE 1 9 C...

Page 17: ...on brushes squeegees harnesses valves cams extraction brushes bearings handle grips filters and finishes f acts of God or g modification of or any part of the product This Limited Warranty does not co...

Reviews: