ENGLISH
30
FEATURES
* The heatable room dimensions are calculated on the basis of pellets with an lhv of at least 4300 kcal/kg and home insulation in compliance
with Italian law 10/91, and subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
It is also important to consider the position of the thermo-stoves in the room to be heated.
A LOT DEPENDS ON THE EFFICIENCY OF THE SYSTEM TERMINALS (heaters).
N.B.
1) Bear in mind that external devices may cause interference.
2) Warning: work on live components, maintenance and /or checks must be performed by qualified personnel.
(Before carrying out any maintenance, disconnect the device from the mains power supply)
ELECTRICAL CHARACTERISTICS
Power supply
/- 10% 50 Hz
On/off switch
yes
Average power consumed
120
W
Average power consumed upon ignition
400
W
Radio control / Remote control frequency
Radio waves 2.4 GHz / Infrared
Main power supply protection **
** Fuse 2A, 250 VAC 5x20
Electronic control board protection
** Fuse 2A, 250 VAC 5x20
SERIAL PORT
The Dealer can install an optional on the AUX outlet for controlling the process of switching on and off (e.g. telephone remote,
local thermostat), located at the rear oh the stove. Can be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board (3-Volt CR 2032 battery). Its malfunction is indicated with the following messages
(not considered a defect but due to normal wear-and-tear): “Battery Check”.
For more detailed information, please contact the DEALER who has performed the first 1st ignition.
The data shown above is purely indicative.
EDILKAMIN reserves the right to make changes to these products to improve their performance with no prior warning.
SAFETY DEVICES
**
FUSE**
two fuses are inserted in the soc-
ket with switch, located on the
back of the stove, one of which
operational and the other is held
in reserve.
THERMOCOUPLE:
placed at the smoke outlet to detect the temperature. Turns the thermo-stoves on and off and
controls its operation based on defined parameters.
VACUUM GAUGE (electronic pressure sensor):
positioned on the smoke extractor, which detects the vacuum value (compared to the
installation environment) in the combustion chamber.
WATER SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out. Reset manually.
TANK SAFETY THERMOSTAT:
trips when the temperature inside the thermo-stoves is too high.
It stops pellet loading, causing the thermo-stoves to go out.
TECHNICAL AND HEATING SPECIFICATIONS
QUEBEC/ TORONTO/MONTREAL DETROIT/ BOSTON/MIAMI
OTTAWA
ATLANTA
Hopper capacity
60
60
100
100
kg
Approx. overall efficiency
93,3
93,2
91,7
92,3
%
Rated power
24
32,6
24
32,3
kW
Water heating power
21
29,3
24
32,3
kW
Min./max. autonomy
11,5 / 37,5
8 / 28
17 / 58
14/ 48
hores
Fuel consumption min./max.
1,6 / 5,3
2,1 / 7,4
1,7 / 5,7
2,1 / 7,4
kg/h
Minimum draught
12
12
12
12
Pa
Max. pressure
3
3
3
3
bar
Operating pressure
1,5
1,5
1,5
1,5
bar
Smoke output temperature from test EN14785
114
142
138
143
°C
CO emission (13% O2)
0,011
0,012
0,056
0,012
%
Weight including packing
390 / 370 / 360
390 / 370 / 359
355
355
kg
Heating capacity *
625
850
625
840
m
3
Diameter of smoke extract duct male thread
10
10
10
10
cm
Summary of Contents for Atlanta
Page 24: ...24 ITALIANO MANUTENZIONE 2 fig A 3 1 fig B fig C fig D 4 3 4 3 2 4 fig E fig F fig G ...
Page 50: ...ENGLISH 50 MAINTENANCE 2 fig A 3 1 fig B fig C fig D 4 3 4 3 2 4 fig E fig F fig G ...
Page 76: ...76 FRANÇAIS ENTRETIEN 2 fig A 3 1 fig B fig C fig D 4 3 4 3 2 4 fig E fig F fig G ...
Page 102: ...102 ESPAÑOL MANUTENCIÓN 2 fig A 3 1 fig B fig C fig D 4 3 4 3 2 4 fig E fig F fig G ...
Page 128: ...128 DEUTSCH WARTUNG 2 Abb A 3 1 Abb B Abb C Abb D 4 3 4 3 2 4 Abb E Abb F Abb G ...
Page 154: ...154 NEDERLANDS ONDERHOUD Afb A Afb B Afb C Afb D 3 4 3 2 4 Afb E Afb F Afb G 2 3 1 4 ...
Page 179: ...664550 03 14 L w w w e d i l k a m i n c o m ...