25
ENGLISH
INSTALLATION
INSTALLER
CHECKING THE ELECTRICAL CONNECTIONS
(the power socket must be located in an
easy-to-access position)
The stove is equipped with an electrical power cord or
connection to a 230V 50 Hz socket, preferably with an
electromagnetic switch.
Variations in voltage of more than 10% can compromise
the operation of the stove.
The electrical system must be compliant; check the
operation of the earth in particular.
Edilkamin is not responsible for malfunctions resulting
from an improperly earthed system.
The power line must be of adequate section for the
power of the appliance.
The power cable must not come into contact with the
flue pipes or other hot parts of the stove.
Power up the stove by shifting its switch from 0 to 1.
There is a 4 A fuse on the socket with switch located at
the rear of the stove.
switch
fuse compartment
power
supply
In certain countries specific regulations apply: it is
the installer's duty to ensure that the local regulations
have been observed.
The technician who sizes the system must assess the
relevant situation.
HOOKING UP OPTIONAL COMPONENTS
There is a terminal board on the product (visible after
removing the right-hand side panel) to which the installer
may connect a home-automation probe or an O.T.A. room
probe for ducted versions. The number of probes that can
be connected is equal to the number of ductable fans.
1-2
3-4
5-6
3 ducting room
probe
2 ducting room
probe
AUX