45
System settings
This operation will restore the following items set from UA-101 Control Panel
to their factory-set state.
• Direct monitor mixer (p. 39)
1
Disconnect the USB cable from the UA-101.
2
Turn the
power switch
all the way toward the left to the
STANDBY
position.
fig.system.eps
3
Press the
digital input switch
,
STEREO/
MONO select switch
, and
direct monitor
soft control switch
to turn them all on
( pressed inward).
4
Set the
sample rate switch
to
192 kHz
.
5
Turn the
power switch
toward the right to turn on the power. The
sync
indicator
will light, then immediately go out.
fig.system-2.eps
6
Within three seconds, turn the
sample rate
select switch
to
96 kHz
. Then, immediately
turn it back to
192 kHz
.
* You must perform these operations no longer than
three seconds apart from each other.
fig.system-3.eps
7
The
input/output level indicators
will blink, and the UA-101 will be reset
to its factory-set state. Turn the UA-101 off, then on again.
Restoring the factory settings
(Factory Reset)
Press
192kHz
ON
96kHz
192kHz
UA-101_e.book 45 ページ 2007年8月6日 月曜日 午後1時23分