3

Auto Range Digital Multimeter - 1000V DC/750V AC

• CAUTION when working with voltages above 60V DC or 30V AC RMS. Such 

voltages pose a shock hazard.

• When using the probes, keep your fingers behind the finger guards.
• Before changing functions, disconnect the test leads from the circuit under 

test.

• Disconnect circuits power & discharge all high-voltage capacitors before 

testing resistance, continuity or diode.

• Before measuring current, turn power off to the circuit before connecting the 

meter to the circuit.

• Change the battery when the  symbol appears to avoid incorrect data.

1.2. Symbols

Symbols used in this manual and on the instrument:

CAUTION:

Refer to the instruction manual. Incorrect use may result 

in damage to the device or its components.
Earth.

This instrument has double insulation.

Fuse: F 500mA/250V.

1.3 Instructions

• Before opening up the multimeter, always turn OFF the device, disconnect 

from all sources of electric current and make sure you are not charged with 
static electricity, which may destroy internal components.

• Any adjustment, maintenance or repair work carried out on the meter should 

only be carried out by a qualified person. 

• If any faults or abnormalities are observed, take the instrument out of service 

and ensure that it is NOT USED until it has been checked and/or re-calibrated 
by a qualified person.

• If the meter is not going to be used for a long time, take out the battery and do 

not store the meter in high temperature or high humidity environment.

• For continuous protection against fire, replace fuse only with the specified 

voltage and current rating: F500mA/250V.

• NEVER use the meter unless the back cover and battery cover are in place and 

fastened fully.

5163100K_Instructions.qxd  17/09/2009  13:54  Page 3

Summary of Contents for DAM075

Page 1: ...o o c co on nt ta ac ct t v vo ol lt ta ag ge e d de et te ec ct to or r W Wi ir ri in ng g f fa au ul lt ts s T Te em mp pe er ra at tu ur re e t te es st te er r f fr ro om m 2 20 0 t to o 1 10 00 0...

Page 2: ...safety only use the test probes supplied with the instrument Before use check the probes are in good condition During use If the meter is used near noise generating equipment be aware that the displa...

Page 3: ...double insulation Fuse F 500mA 250V 1 3 Instructions Before opening up the multimeter always turn OFF the device disconnect from all sources of electric current and make sure you are not charged with...

Page 4: ...and ranges This key selects Automatic default or manual mode 1 1 To switch from auto to manual mode a a Select your desired test range V V or b b Press the R RA AN NG GE E button for 1 sec a beep wil...

Page 5: ...D lead for voltage resistance capacitance diode continuity measurements temperature and frequency 3 TECHNICAL SPECIFICATIONS 3 1 General Specifications Environment conditions CAT III 600V and CAT II 1...

Page 6: ...ng number of digits at 18 C to 28 C 64 F to 82 F with relative humidity to 80 No Contact AC Voltage Detector DC Voltage Input impedance 10M Maximum input voltage 1000V DC or 750V AC rms AC Voltage Inp...

Page 7: ...DC or 10A AC rms for 10A ranges Frequency Range 40Hz 400Hz Response Average calibrated in rms of sine wave Resistance Open circuit voltage approx 0 25V Overload protection 250V DC or 250V AC rms RANGE...

Page 8: ...sistance is less approximate 0 5V than approx 40 Display read approx Forward DC Current forward voltage of diode Approx 1mA Reversed DC Voltage approx 1 5V RANGE RESOLUTION ACCURACY 20 C to 0 C 1 C 5...

Page 9: ...k k a an nd d o or r d da am ma ag ge e t to o t th he e m mu ul lt ti im me et te er r D DO O N NO OT T a at tt te em mp pt t t to o t ta ak ke e a an ny y v vo ol lt ta ag ge e m me ea as su ur re e...

Page 10: ...n circuit the figure O OL L will be displayed for the overrange condition Diode Measurement T To o a av vo oi id d e el le ec ct tr ri ic ca al l s sh ho oc ck k a an nd d o or r d da am ma ag ge e t...

Page 11: ...e a few seconds 200mF range 30 seconds to stabilise reading This is normal for high capacitance measuring To improve the accuracy of measurements less than 4nF subtract the residual capacitance of the...

Page 12: ...making a DC measurement 6 6 When the figure OL is displayed a beep will sound continually this indicates an overrange situation and the higher range has to be selected Misplug Alarm T To o a av vo oi...

Page 13: ...a ac ci in ng g t th he e b ba at tt te er ry y a an nd d f fu us se es s d di is sc co on nn ne ec ct t t te es st t l le ea ad ds s f fr ro om m a an ny y c ci ir rc cu ui it t u un nd de er r t te...

Page 14: ...er and then the battery cover Replace the fuse only with a 500mA 250V 5 20 Replace the 2 back covers and screw securely back into place The multimeter should now be fully functional 6 PACK CONTENTS Di...

Page 15: ...15 Auto Range Digital Multimeter 1000V DC 750V AC 5163100K_Instructions qxd 17 09 2009 13 55 Page 15...

Page 16: ...developed and improved All details and illustrations are for guidance and may be subject to change EDISON The Power Factory PO Box 14 Wigston Leicester England ISO 9001 Registered Company 5163100K_Ins...

Reviews: