7
Auto Range Digital Multimeter - 1000V DC/750V AC
DC Current
• Overload protection: F 500mA/250V fuse for uAmA range.
• Maximum input current:
- 400mA DC or 400mA AC rms for µA and mA ranges.
- 10A DC or 10A AC rms for 10A ranges.
AC Current
• Overload protection: F 500mA/250V fuse for uAmA range.
• Maximum input current:
- 400mA DC or 400mA AC rms for µA and mA ranges.
- 10A DC or 10A AC rms for 10A ranges.
• Frequency Range: 40Hz-400Hz.
• Response: Average, calibrated in rms of sine wave.
Resistance
• Open circuit voltage: approx. 0.25V
• Overload protection: 250V DC or 250V AC rms.
RANGE
RESOLUTION
ACCURACY
400
Ω
0.1
Ω
4k
Ω
1
Ω
40k
Ω
10
Ω
±(1.2% of rdg +3 digits)
400k
Ω
100
Ω
4M
Ω
1k
Ω
40M
Ω
10k
Ω
±(2.0% of rdg +5 digits)
RANGE
RESOLUTION
ACCURACY
4000µA
1µA
±(1.2% of rdg +3 digits)
400mA 0.1mA
10A
10mA
±(2.0% of rdg +8 digits)
RANGE
RESOLUTION
ACCURACY
4000µA
1mµA
±(1.5% of rdg +5 digits)
400mA 0.1mA
10A
10mA
±(3.0% of rdg +8 digits)
5163100K_Instructions.qxd 17/09/2009 13:55 Page 7