background image

9

Auto Range Digital Multimeter - 1000V DC/750V AC

Frequency

• Overload protection: 250V DC or 250V AC rms.
• Input voltage range: 0.6~3V AC rms (Input voltage must be enlarged with 

increasing frequency under measurement).

4. O P E R A T I N G   I N S T R U C T I O N
No contact AC voltage detector

T

Th

he

erre

e  iis

s  n

no

o  ‘‘A

Au

utto

o  P

Po

ow

we

err  O

Offff’’  ffu

un

nc

cttiio

on

n  o

on

n  tth

hiis

s  s

se

ettttiin

ng

g..  

T

Th

he

e                  ((b

ba

ac

ck

klliig

gh

htt))  iis

s  n

no

ott  o

op

pe

erra

attiiv

ve

e  iin

n  tth

hiis

s  rra

an

ng

ge

e..

1

1.. Set dial to the           symbol. 
2

2.. When meter is switched on a Green LED light will appear lit.
3

3.. Put the ‘EF-DETECT AREA’ (top end) close to a lead or power socket, if AC 

electrical voltage is present the Red LED indicator will flash and you will hear 
a repetitive warning beep,  figure will also be displayed on the LCD screen.

Voltage Measurement

T

To

o  a

av

vo

oiid

d  e

elle

ec

cttrriic

ca

all  s

sh

ho

oc

ck

k  a

an

nd

d/

/o

orr  d

da

am

ma

ag

ge

e  tto

o  tth

he

e  m

mu

ullttiim

me

ette

err,,  

D

DO

O  N

NO

OT

T  a

atttte

em

mp

ptt  tto

o  tta

ak

ke

e  a

an

nyy  v

vo

olltta

ag

ge

e  m

me

ea

as

su

urre

em

me

en

ntt  tth

ha

att  m

miig

gh

htt  

e

ex

xc

ce

ee

ed

d  1

10

00

00

0V

VD

DC

C  o

orr  7

75

50

0V

VA

AC

C  rrm

ms

s..  D

Do

o  n

no

ott  a

ap

pp

pllyy  m

mo

orre

e  tth

ha

an

n  

1

10

00

00

0V

VD

DC

C  o

orr  7

75

50

0V

VA

AC

C  rrm

ms

s  b

be

ettw

we

ee

en

n  tth

he

e  c

co

om

mm

mo

on

n  tte

errm

miin

na

all  a

an

nd

d  tth

he

e  e

ea

arrtth

h  g

grro

ou

un

nd

d..

1

1.. Set rotary switch to the V (ACV or DCV) range.
2

2.. Press “RANGE” key to select manual mode.
3

3.. Connect the Black and Red test leads to the COM and V terminals respectively.
4

4.. Connect the test leads to the circuit being measured.
5

5.. Read the displayed value. The polarity of red test lead connection will be indicated 

when taking a DC measurement.

RANGE

RESOLUTION

ACCURACY

9.999Hz

0.001Hz

99.99Hz

0.01Hz

999.9Hz

0.1Hz

±(0.1% of rdg +1 digit)

9.999kHz

1Hz

99.99kHz

10Hz

199.9kHz

100Hz

>200kHz

100Hz

Unspecified @ >200kHz

5163100K_Instructions.qxd  17/09/2009  13:55  Page 9

Summary of Contents for DAM075

Page 1: ...o o c co on nt ta ac ct t v vo ol lt ta ag ge e d de et te ec ct to or r W Wi ir ri in ng g f fa au ul lt ts s T Te em mp pe er ra at tu ur re e t te es st te er r f fr ro om m 2 20 0 t to o 1 10 00 0...

Page 2: ...safety only use the test probes supplied with the instrument Before use check the probes are in good condition During use If the meter is used near noise generating equipment be aware that the displa...

Page 3: ...double insulation Fuse F 500mA 250V 1 3 Instructions Before opening up the multimeter always turn OFF the device disconnect from all sources of electric current and make sure you are not charged with...

Page 4: ...and ranges This key selects Automatic default or manual mode 1 1 To switch from auto to manual mode a a Select your desired test range V V or b b Press the R RA AN NG GE E button for 1 sec a beep wil...

Page 5: ...D lead for voltage resistance capacitance diode continuity measurements temperature and frequency 3 TECHNICAL SPECIFICATIONS 3 1 General Specifications Environment conditions CAT III 600V and CAT II 1...

Page 6: ...ng number of digits at 18 C to 28 C 64 F to 82 F with relative humidity to 80 No Contact AC Voltage Detector DC Voltage Input impedance 10M Maximum input voltage 1000V DC or 750V AC rms AC Voltage Inp...

Page 7: ...DC or 10A AC rms for 10A ranges Frequency Range 40Hz 400Hz Response Average calibrated in rms of sine wave Resistance Open circuit voltage approx 0 25V Overload protection 250V DC or 250V AC rms RANGE...

Page 8: ...sistance is less approximate 0 5V than approx 40 Display read approx Forward DC Current forward voltage of diode Approx 1mA Reversed DC Voltage approx 1 5V RANGE RESOLUTION ACCURACY 20 C to 0 C 1 C 5...

Page 9: ...k k a an nd d o or r d da am ma ag ge e t to o t th he e m mu ul lt ti im me et te er r D DO O N NO OT T a at tt te em mp pt t t to o t ta ak ke e a an ny y v vo ol lt ta ag ge e m me ea as su ur re e...

Page 10: ...n circuit the figure O OL L will be displayed for the overrange condition Diode Measurement T To o a av vo oi id d e el le ec ct tr ri ic ca al l s sh ho oc ck k a an nd d o or r d da am ma ag ge e t...

Page 11: ...e a few seconds 200mF range 30 seconds to stabilise reading This is normal for high capacitance measuring To improve the accuracy of measurements less than 4nF subtract the residual capacitance of the...

Page 12: ...making a DC measurement 6 6 When the figure OL is displayed a beep will sound continually this indicates an overrange situation and the higher range has to be selected Misplug Alarm T To o a av vo oi...

Page 13: ...a ac ci in ng g t th he e b ba at tt te er ry y a an nd d f fu us se es s d di is sc co on nn ne ec ct t t te es st t l le ea ad ds s f fr ro om m a an ny y c ci ir rc cu ui it t u un nd de er r t te...

Page 14: ...er and then the battery cover Replace the fuse only with a 500mA 250V 5 20 Replace the 2 back covers and screw securely back into place The multimeter should now be fully functional 6 PACK CONTENTS Di...

Page 15: ...15 Auto Range Digital Multimeter 1000V DC 750V AC 5163100K_Instructions qxd 17 09 2009 13 55 Page 15...

Page 16: ...developed and improved All details and illustrations are for guidance and may be subject to change EDISON The Power Factory PO Box 14 Wigston Leicester England ISO 9001 Registered Company 5163100K_Ins...

Reviews: