Replace the
Fuser-Roller
Pressure-Release
Pieces
QMS magicolor WX User
’
s Guide
6-8
2
Open the pressure-release lever on the end of the fuser unit.
M
WARNING!
The fuser unit can become extremely hot and cause
severe burns. Make sure the unit is cool before handling it.
ACHTUNG!
Die Fixiereinheit kann sehr heiß werden, so daß
Verbrennungs-gefahr besteht. Bitte lassen Sie die Fixiereinheit
einige Zeit abkühlen, bevor Sie diese berühren.
3
Holding one of the pieces down close to its base, firmly slide
the base between the fuser rollers on one end.
Rear View
EDNord - Istedgade 37A - 9000 Aalborg - telefon 96333500