E D R O
D
y n a
W
a s h
®
T
h r e e
P
o c k e T
W
a s h e r
- e
x T r a c T o r s
20
STANDARD ELECTRICAL CONNECTIONS
DW100
DW150
DW200
DW300
DW400
Wire Size
#6 AWG
#6 AWG
#6 AWG
#2 AWG
#2 AWG
Circuit Breaker
30 AMP
50 AMP
50 AMP
100 AMP
100 AMP
208 - 240 volts / 3 phase / 60 cycle:
440 - 480 volts / 3 phase / 60 cycle:
DW100
DW150
DW200
DW300
DW400
Wire Size
#12 AWG
#10 AWG
#10 AWG
#6 AWG
#6 AWG
Circuit Breaker
20 AMP
25 AMP
25 AMP
50 AMP
50 AMP
380 - 415 volts / 3 phase / 50 cycle:
DW100
DW150
DW200
DW300
DW400
Wire Size
#10 AWG
#8 AWG
#8 AWG
#6 AWG
#6 AWG
Circuit Breaker
25 AMP
30 AMP
30 AMP
60 AMP
60 AMP
NOTE
Options such as Water Reuse System and Electric Heating
Element will require larger wire sizes and must be
determined at site by a qualified electrician. Contact
Factory for Electrical Connections not listed.
2 MOTOR - 3 SPEED DRIVE
DW100
DW150
DW200
DW300
DW400
Wire Size
#6 AWG
#6 AWG
#6 AWG
#2 AWG
#2 AWG
Circuit Breaker
30 AMP
30 AMP
50 AMP
80 AMP
100 AMP
230 volt / 3 phase / 60 cycle:
460 volt / 3 phase / 60 cycle:
DW100
DW150
DW200
DW300
DW400
Wire Size
#12 AWG
#10 AWG
#10 AWG
#6 AWG
#6 AWG
Circuit Breaker
20 AMP
20 AMP
25 AMP
40 AMP
50 AMP
SINGLE MOTOR