background image

DynaTrol HMI Touch Screen Control 

Page 25 

 

 

 
COPY PROGRAM 
To speed programming of similar wash programs, select the copy program function.  A 
level 2 password is required. 
 

 

 
RESET FACTORY PROGRAMS 
Resets wash programs to factory defaults.  A level 2 password is required.  This action 
cannot be undone. 
 
CLEAR PROGRAM NAMES 
Clears all wash program names and reverts to “Program 1”, “Program 2”, “Program 3”, 
etc.  A level 2 password is required.  This action cannot be undone. 
 

Summary of Contents for DYNATROL HMI

Page 1: ...AMMING OPERATION PARTS REFERENCE MANUAL DYNATROL HMI TOUCH SCREEN CONTROL For DynaWash Washer Extractors Includes DynOzone Programming and Operation HMI Code 1 00 Technical specifications are based on the latest information available at the time of printing and are subject to change without notice ...

Page 2: ...d and Start a Program 12 AutoStart 13 Wash Screen 13 Override Mode 14 Drain Screen 14 Extract Screen 15 Program Complete 15 Alarms and Warnings 16 Reports 17 Alarms 18 Counters 19 Program History 20 Technical Information 21 On Screen Control Manual 21 Debug Screens 22 Settings 24 Passwords 24 Copy Program 25 Reset Factory Programs 25 Clear Program Names 25 Transfer Programs 26 Default Factory Prog...

Page 3: ...r and Supervisor Modes Managerial Reports on Operation Technical Information and Troubleshooting Settings The DynaTrol touch screen control can be setup to work on any DynaWash washer extractor It must be properly configured to take full advantage of its capabilities MACHINE CONFIGURATION To enter Machine Configuration press the Configuration button from the Home screen then select Machine Configu...

Page 4: ...DynaTrol HMI Touch Screen Control Page 3 Select a model ...

Page 5: ... button is located next to each parameter which further describes the necessary input or provides a means to set the value Enter or change a value by pressing the corresponding number box on the right side of the screen A popup window will appear with the current parameter value Enter a new value and press ENT to accept CLR to clear and the X to return without saving MOTOR SETUP Configures motor d...

Page 6: ...DynaTrol HMI Touch Screen Control Page 5 OZONE SIGNAL SETUP Configures DynOzone system and signals working parameters TIMERS SETUP Configures values which are affected by timers ...

Page 7: ...E SETUP To choose Language press the Configuration button from the Home screen Then select the Language button A level 4 password is required to enter Select an available language This will change all screens except technical information screens to the selected language Technical information screens are by default English ...

Page 8: ...rom the Home screen Then select the Wash Programming button A Level 2 password is required to enter Begin by selecting a wash program number Use the buttons to scroll Program names appear in the text box Twenty factory programs are preloaded These may be edited deleted or re loaded To edit name press the text box From this screen you can select a program change program name return to previous menu...

Page 9: ...ad a program summary screen delete button which will delete a step insert button which will insert a step or edit button to edit the step WASH RINSE Step A Wash Rinse step may contain the following operations Water fill temperature control rotation control DynOzone control and signal control A time must be entered for any wash rinse step WATER FILL Press Cold to activate cold valve Hot for hot val...

Page 10: ...nclude Standard Wash Delicate Wash Fluff Forward Only Reverse Only No Rotation When selecting Standard Wash Delicate Wash or Fluff a new screen will popup with default settings which can then be accepted or modified DYNOZONE CONTROL Selecting the Ozone button will activate the DynOzone system during the wash step System will start based on the configured step start parameters and continue for the ...

Page 11: ...n or reuse Drain option LEVEL CONTROL Program a time and select level 0 or select a water level without time to drain to a set point EXTRACT Step An Extract step may contain the following operations Speed selection Sewer Drain Reuse Drain option A time must be entered for an extract step SPEED SELECTION Depending on motor configuration select a speed for extraction DRAIN CONTROL Select either sewe...

Page 12: ...NK PROGRAM Pressing the Link Program button create a program link to any program in memory END PROGRAM Pressing the End Program button will delete all latter steps of the program When the Return button is pressed from the main wash programming screen a program summary will appear detailing all programmed steps Press Next to scroll through all 25 steps or Program Select to return to Configuration m...

Page 13: ...n key Door is active to allow opening of the door for loading machine Press the Load Program button to go to Start screen On Start screen all function keys are active Select the appropriate operation START begins program operation STOP pauses machine operation AUTOSTART allows for starting the machine at a time in the future A popup screen contains date and time and activation key DOOR activates d...

Page 14: ...o back to Start screen WASH SCREEN The header indicates the program number program name step number and step status The body contains bar graphs indicating current water level and current temperature with a grey bar for programmed set points Flashing indicators illuminate for water fill valves heating DynOzone operation and signal outputs The footer indicates step time and program time Pressing st...

Page 15: ...de during override function and requires the return button and start key to continue or end program or stop button to abort DRAIN SCREEN The header indicates the program number program name step number and step status The body contains bar graphs indicating current water level and current temperature with a grey bar for programmed set points The footer indicates step time and program time Times in...

Page 16: ...footer indicates step time and program time Times indicate remaining time The override function is not available in an extract step PROGRAM COMPLETE At end of program a Program Complete screen will appear and buzzer will sound After safety brake time and safe mode conditions are meet the door can be opened and goods removed Return button on Program Complete screen goes to Load Program screen with ...

Page 17: ...o safe mode Reset component Alarm History screen appears with list of last 100 alarms List of Alarms Emergency Stop Wash Motor Overload Extract Motor Overload VFD Overload Door Open During Operation Low Air Supply Ozone Pump 1 Failure Ozone Pump 2 Failure PowerCell bank less than 50 Out of Balance Failure Sample Warning Water Level Timeout Machine sent to pause mode Reset timer or override warning...

Page 18: ... Page 17 REPORTS The following reports categories are available for viewing the machine s history of operation Alarms Counters Program History To view Reports press the Configuration button from the Home screen then select the Reports ...

Page 19: ...ch Screen Control Page 18 ALARMS There are three alarm reports Current Alarms are active machine alarms Alarm History contains the last 100 alarms Alarm Frequency details the number of times a particular alarm occurred ...

Page 20: ...t Total Machine Run Time counts hours of machine operation Total Programs Run counts total programs Power Cycles count On Off Service Timers count the hours of operation from the last reset These timers are tied into the service maintenance pop up screens and are re settable with password security ...

Page 21: ...ontrol Page 20 PROGRAM HISTORY View the last 50 programs run with a time stamp and the total number of times for each Program Run Counters may be reset to zero by pressing the program count number and entering a Level 2 password ...

Page 22: ...l Number and Serial Number on the Home screen Use this information whenever contacting EDRO technical support for assistance To enter DynaTrol s technical information section press the Configuration button from the Home screen Then select the Technical Information button A password is not required to continue ON SCREEN CONTROL MANAUL Select the DynaTrol Control Manual button to proceed ...

Page 23: ...posees Proceed with caution as interlocking safety features are disabled Do not wash clothes using the Debug Screens The Debug Screen home page Select a range of inputs outputs for troubleshooting The I O Lists button illustrates all inputs and outputs A red light will appear next to the active ones Refer to the machine schematic for X input and Y output descriptions Plumbing Outputs Use the elect...

Page 24: ... Motor Outputs Use the electronic toggle switches to activate deactivate outputs DynOzone system Use the electronic toggle switch to activate deactivate system Hardware outputs Use the electronic toggle switches to activate deactivate outputs ...

Page 25: ...curity A user can only operate screens granted by their security level Higher level passwords control all functions and settings of lower level passwords For example a level 2 user has all the authority of level 2 and level 1 users and ability to change both level 2 and level 1 passwords Machines are shipped from the factory with the following passwords settings Level Description Default Password ...

Page 26: ...m function A level 2 password is required RESET FACTORY PROGRAMS Resets wash programs to factory defaults A level 2 password is required This action cannot be undone CLEAR PROGRAM NAMES Clears all wash program names and reverts to Program 1 Program 2 Program 3 etc A level 2 password is required This action cannot be undone ...

Page 27: ...Follow screen instructions DEFAULT FACTORY PROGRAMS 1 Light Soil Ozone 2 Light Soil 2 Ozone 3 Medium Soil Ozone 4 Medium Soil 2 Ozone 5 Heavy Soil Ozone 6 Delicates Ozone 7 Delicates 2 Ozone 8 3 Hour Soak Ozone 9 Rinse and Spin Ozone 10 Stain Buster Ozone 11 Light Soil 12 Light Soil 2 13 Medium Soil 14 Medium Soil 2 15 Heavy Soil 16 Delicates 17 Delicates 2 18 3 Hour Soak 19 Rinse and Spin 20 Stai...

Page 28: ... BACKLIGHT Sets the brightness and contrast of the display HMI CONFIGURATION SETTINGS Buzzer o Turns ON or OFF the beeping sound activated by touching the display Screen Saver o Powers off the display after set amount of time o Feature does not turn off machine Power light on display still active Boot Delay o Set from factory do not adjust Language o 1 English Print o Not used COM1 o RS232 9600 CO...

Page 29: ... and a 10 inch version 6537 TS6 DISPLAY DYNATROL 6 6537 TS10 DISPLAY DYNATROL 10 6537 1 POWER SUPPLY DYNATROL 6537 2 PLC DYNATROL 6537 3 DIGITAL I O MODULE ELC DYNATROL 6537 8 PRESSURE SENSOR WATER LEVEL 6537 9 CABLE HMI MALE MALE RS232 DB9 6537 16 CABLE CABLE INTERCONNECT TS DYNATROL COMMUNICATIONS PROGRAM TRANSFER ...

Reviews: