Embedded Data Systems, LLC; 2019 Fortune Dr., Lawrenceburg, KY 40342; Phone/Fax 502-859-5490 24 / 37
EN-USERMAN OW-SERVER-ENET-2 V2.0 12.20.12
In order to complete the connection, you must enter the username
1
and password.
2
Once the connection has been successfully authenticated, the OW-SERVER-ENET-2 will pre-
sent you with a textual menu through which you can show basic information.
UDP
The OW-SERVER-ENET-2 can interact with UDP requests on port 30303 and provide basic in-
formation in return. The primary use for this is discovering any OW-SERVER-ENET-2 on the
network, such as with the EDS Appliance Scanner Software. You can download a copy of this
free OW-SERVER discovery application (available for Windows OS, Apple OS X, and Linux)
from the EDS website. A link to the software is provided in the EDS Appliance Scanner section
of this manual.
The OW-SERVER-ENET-2 sends a UDP broadcast packet to port 30303 when:
•
First powered up
•
IP address changes due to a new DHCP server lease
•
When the letter ‘
D
’ is received on UDP port 30303, either directly or via a UDP broadcast.
The following is an example of the UDP packet:
{"NETBios": "EDSOWSERVER ",
"MAC": "00-50-C2-91-B1-44",
"IP": "192.168.1.14",
"Product": "OW_SERVER-Enet-2",
"FWVer": "1.01",
"Name": "OW_SERVER-Enet-2",
"HTTPPort": "80",
"Bootloader": "POST",
"TCPIntfPort": "0",
}
1
Factory default "admin"
2
Factory default "eds"