background image

EDS - TECHNICAL INSTRUCTIONS

23

1. OBJECT

EDS S.r.l. - Via Cà Nova Zampieri 6, 37057 S. G. Lupatoto - Verona,
Italy (hereinafter “EDS”), guarantees its products to be free from
defects in materials or workmanship within the terms and conditions
of this Warranty. A product found by EDS to be defective will be
repaired or replaced, at the option of EDS, within 24 month after
receipt of the product by EDS or an authorized EDS Service Center.
Please note that in addition to this policy you may have specific legal
rights granted by your national or state laws regarding warranties of
consumer products.

2. NOT COVERED

This warranty does not cover products which reached the end of
their  normal  lifespan,  does  not  cover  damage  resulting  from
accidents, alteration, neglect, misuse or abuse, lack of reasonable
or  proper  maintenance,  corrosion,  improper  assembly,  repairs
improperly performed or replacement parts improperly installed, use
of replacement parts or accessories not conforming to EDS’s
specifications, use of component parts not manufactured or supplied
by EDS, modifications not recommended or approved in writing by
EDS, normal wear and deterioration occasioned by the use of the
product. This warranty also does not cover cosmetic imperfections
in  the  surface,  finish,  or  appearance  of  the  product  which  were
apparent or discoverable at the time of purchase of the product or
damage occurring during shipment or transport of the product. This
warranty also does not cover tools and other consumables or any
expenses related to the transportation of the product to or from EDS
or an authorized EDS Service Center.

3. PURCHASER

This warranty is made only with the original purchaser of the product
and does not extend to any third parties. The rights of the Purchaser
under this warranty may not be assigned.

4. TERM

The  term  of  this  warranty  shall  commence  on  the  date  of  retail
purchase and shall continue for a period of 24 month.

5. ENTIRE AGREEMENT

This  warranty  supersedes  any  and  all  oral,  express  or  written
warranties, statements orundertakings that may previously have
been made, and contains the entire Agreement of the parties with
respect to the warranty of the product. Any and all warranties not
contained in this Agreement are specifically excluded.

6. DAMAGES

Except  as  expressly  provided  by  this  warranty,  EDS  shall  not  be
responsible for any incidental or consequential damage associated with
the use of the product or a claim under this agreement, whether the
claim is based on contract, tort or otherwise. The foregoing statements
of warranty are exclusive and in lieu of all other remedies.Some states
do not allow the exclusion or limitation of incidental or consequential
damages, so this limitation or exclusion may not apply to you.

7. DISCLAIMER

Any implied warranty of merchantability or fitness for a particular
purpose and all implied warranties arising from a course of dealing,
usage of trade, by statute or otherwise, is hereby strictly limited to
the term of this written warranty. This agreement shall be the sole
and exclusive remedy available to the Purchaser with respect to the
purchase. In the event of any alleged breach of any warranty or any
legal action brought by the purchaser based on alleged negligence
or other tortuous conduct by EDS, the Purchaser’s sole and exclusive
remedy will be repair or replacement of defective materials as stated
above. No dealer and no other agent or employee of EDS is authorized

to modify, extend or enlarge this warranty. The performance of any
warranty  service  under  this Agreement  is  not  an  admission  or
agreement that the design or manufacture of a product is defective.

8. PROCEDURE

In the event of a defect covered by this warranty, the purchaser should
contact EDS - Via Cà Nova Zampieri 6, 37057 S. G. Lupatoto - Verona,
Italy or an authorized EDS Service Center. To be honored, claims
must be submitted within the 24 month warranty period (according
to the product) and within eight (8) days of discovery of the defect.
The determination whether the defect is covered by this warranty is
within  the  sole  discretion  of  EDS.  EDS  reserves  the  right  to
discontinue  products  and  to  change  specifications  for  existing
products at any time without notice and shall not be obligated to
incorporate new features into products previously sold, even if those
products are returned under a warranty claim. EDS may replace
defective parts with similar parts of similar quality in the event that
identical parts are unavailable. The purchaser must obtain advance
authorization  in  writing  before  returning  any  product  to  EDS  for
warranty inspection. A return authorization number will be issued and
must conspicuously appear on the outside of the product’s packaging.
The  issuance  of  an  authorization  number  does  not  constitute
acceptance of the claim, which will be evaluated by EDS upon its
inspection of the product. The product should be cleaned and securely
packed  to  prevent  damage  during  shipment  and  must  be
accompanied by a letter specifying or including the following items
of information:

a) dated receipt or other proof of date of retail purchase;
b) a copy of the warranty;
c) EDS part number;
d) detailed description of the problem experienced with the product,
including a chronology of efforts made to correct the problem;
e)  identification  of  the  components  used  in  conjunction  with  the
product;
f) estimate of product usage: (i.e. accumulated mileage or time in
service);
g) your name, address, and written authorization to ship the repaired
product back to you freight collect (“C.O.D.”);
h) the product for repair must be shipped to EDS without any charge

9. APPLICABLE LAW

Any disputes arising out of this Agreement or the use of this product
will be governed by the laws of
the country of Italy and will be decided by the Courts of Verona, Italy.

EDS  WARRANTY  GENERAL  CONDITIONS

Summary of Contents for RK 100 RS

Page 1: ...CAL BEAM SMOKE DETECTOR RK100 R RK100 RS with Laser Pointer BLP 100 TECHNICAL MANUAL TECHNICAL INSTRUCTIONS FOR INSTALLATION SETUPAND MAINTENANCE EDS V Ca Nova Zampieri 6 37057 S G Lupatoto VERONA Tel 39045547529 Fax 390458750065 eds eds eu www eds eu ...

Page 2: ...nce 17 Sensitivity selection 18 Technical data DEFAULT FACTORYSETTINGS Read ahead SW1 position 1 minimum threshold level SW2 position 1 minimum threshold level SW3 position 4 maximum Transmitter power JP1 position 2 3 optical allignment on JP2 JP3 position 2 3 contact NC JP4 position 1 2 contact NC for Fault relay JP5 position 1 2 memory off JP7 not inserted alarm relays NC P1 level adjustment tri...

Page 3: ...vice according to the distance between Detector and FX see table in fig 7 6 place jumper JP1 in ON position Alignment and power up the device 7 optimize the device signal using the P1 trimmer the adjustment screws V1 V2 V3 on the optical block a multimeter or the STS01 instrument blue Red Led signal level indication fig 8 board 8 regulate the signal between 4 7V and 5V with the P1 trimmer 9 verify...

Page 4: ...cording to the tecnical data and to the information of this manual to the installation and to the ambiental and operational condition 2 RELEVANTSTANDARDS 2 1 For the installation in European Community countries you must follow the EC standard EN54 14 Fire detection and fire alarm systems In extraeuropean countries you must respect the relevant international and national standards 3 INSTALLATION 3 ...

Page 5: ...ontact relay Connection is valid when the detector is not in an alarm state and JP3 jumper is in 2 3 position If JP3 is positioned on 1 2 the contact results normally open C2 N2 terminals are voltage free C3 N3 normally closed fault relay contact Fault relay is normally powered intrinsic safety Connection is valid when the detector is not in Fault state and JP4 jumper is in 1 2 position If JP4 is ...

Page 6: ...ct this variation and when these reach the amplitude and the duration in the time programmed a alarm signal is produced The sensitivity and the delay of intervention of this circuit are independently adjustable so that to fully satisfy the applications of the technician The advantage offered by this circuit is a great speed of fire detection because it is detected in dynamic way in its initial pha...

Page 7: ...ned for this application that must be inserted on the special connector CN4 set on the printed circuit of the detector v fig 11 If you don t have a Multimeter or the STS01 you can perform the setup operations anyway evaluating the signal level with the frontal Leds indications as described in chap 8 12 8 8 If available connect a 5V fullscale Multimeter between the SIG terminal and the negative pow...

Page 8: ...one are off if the signal in the range 0 5 1 V the red led performs 1 flash remains off for 2 seconds and then it repeats the sequence if signal is among 1 1 5 V the blue led flashes once remains off for 2 seconds and then it repeats the sequence if signal is among 1 5 2V the blue led flashes once and the red led flashes once They remain off for 2 seconds and then the sequence is repeated if signa...

Page 9: ...d at distances from the ceiling higher than the nominal When the fire begins it produces smoke clouds and hot air bubbles that go up When these bubbles intercept the infrared beam they perturbate it because they produce a change of the optical physical characteristics of infrared beam These changes are obviusly correlated in time This circuit has been designed to detect these changes and when thes...

Page 10: ...l it doesn t stop the alarm and is not removed power for over 5 seconds When the memory is not activated if the detector goes to alarm the alarm relay and the frontal Led are disarmed as soon as it stops the alarm 12 2 Memory of the data of configuration and setting In case of black out the memory inside preserve the data To the return of the feeding the detector later once of initialization of ab...

Page 11: ... 16 MAINTENANCE 16 1 The instrument asks for a simple and periodic maintenance It can be programmed or made automatic on special signaling of the detector During the normal operation and after a certain time from the installation if the maintenance is not performed the detector because of the dirt deposited on the front surface of the cover produces a Fault signal because of the drop of the signal...

Page 12: ...or 0 5 Maximumangularmissallignmentofthereflector 0 5 Selectionoftheobscurationalarmthresholdlevelwitha4positionsswitch position1 70 position2 60 position3 50 position4 40 Selectionoftheturbulencealarmthresholdlevelwitha4positionsswitch AlarmRelayactivationdelay 10s FaultRelayactivationdelay 5s Detector s recovery time with alarm memory dectivated about 5s Detector s recovery time with alarm memor...

Page 13: ...disco bianco white disc diodo fotoemittente photoemitting diode foro hole 0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 distanza m diametro del raggio cm 70 80 90 100 fig 1 fig 2 fig 3 fig 4 fig 5 fig 6 A A A A rivelatore riflettore ...

Page 14: ... 8 0 7 4 0 9 0 8 3 0 X F 1 0 8 0 7 2 0 9 0 8 3 0 0 1 0 9 4 0 1 1 0 0 1 0 1 X F 1 8 5 0 5 2 5 6 8 5 3 5 7 5 6 4 5 8 5 7 fig 7 fig 8 G N I H S A L F T L O V N O I T A L E R T L O V h s a l F N d e L e u l B h s a l F N d e L d e R 5 0 F F O F F O 1 5 0 F F O 1 5 1 1 1 F F O 2 5 1 1 1 5 2 2 2 F F O 3 5 2 2 1 5 3 3 3 F F O 4 5 3 3 1 7 4 4 e l b a i r a V F F O 5 9 4 7 4 t h g i l x i F F F O 5 9 4 n o...

Page 15: ... e p o y l l a m r o n t c a t n o c y a l e r 5 P J 2 1 F F O y r o m e m m r a l a 3 2 N O y r o m e m m r a l a 6 P J N O t e s e r F F O 8 P J N O n o i t p o t l u a F n o i t a r u c s b o l a t o t d e t a v i t c a F F O n o i t p o t l u a F n o i t a r u c s b o l a t o t d e t a v i t c a t o n 7 P J 2 P J S R E P M U J G N I T T E S r e p m u J n o i t i s o P t l u s e R 7 P J 2 P J 2...

Page 16: ...3 1 2 3 1 2 3 JP2 JP4 JP3 alarm relay turbo relay fault relay P1 JP7 1 2 3 CN4 SW1 SW2 SW3 TURBO SENS POWER ON OFF ALI ON OFF MEM 1 2 3 4 5 6 7 8 9 V1 V2 V3 LED di Allarme LED di Allineamento RX TX JP6 Alarmrelais Turborelais Fehlerrelais DS1649A Relè Guasto Turbo Relè Relè Allarme JP8 ...

Page 17: ...ON alignment procedure activated JP1 position 1 2 OFF alignment procedure deactivated JP2 JP3 JP4 Jumpers to set the relay contacts respectively of the alarm relay turbulence if present and fault normally closed NC or normally open NO position 1 2 output contact normally open NO position 2 3 output contact normally closed NC JP4 must be in position 1 2 to have the contact closed because the fault ...

Page 18: ...voltage 11 30 Vcc ALARM relay contact TURBULENCE relay contact FAULT relay contact analog signal output 0 5V 1 2 3 4 5 6 7 8 9 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 JP1 1 2 3 JP5 1 2 3 1 2 3 1 2 3 JP2 JP4 JP3 alarm relay turbo relay fault relay P1 JP7 SW1 SW2 SW3 TURBO SENS POWER ON OFF ALI ON OFF MEM 1 2 3 4 5 6 7 8 9 V1 V2 V3 LED di Allarme LED di Allineamento RX TX JP6 Alarmrelais Turborelais Fehlerrel...

Page 19: ...nit In this case the detector is a zone of the system The state of the indicated relays correspond to the normal operation condition of the detector Thealarmoutputistheoneofthealarmrelay circuitsensibletoobscurationinalarm ortheonefromtheturbulencerelay circuitsensibletoturbulence heat inalarm The turbulence relay if not necessary can be left unused The fault output is the one from the NC contact ...

Page 20: ...e This base is available with the same color of the base of the detector red or white STS 01 Small analog meter for analog output signal measuring It must be used inserting it on suitable connector on the PCB during the operation of optical alignment Voltage Range 0 5 V EV570 5 Bar Graph Voltmeter It allows the remote measuring of the analog output signal of the optical beam smoke detectors RK90R ...

Page 21: ... 4 Name registered trade name or registered trademark and contact address of the manufacturer as required pursuant to article 11 5 EDS srl Via Cà Nova Zampieri 6 San Giovanni Lupatoto Verona 37057 Italy 5 Where applicable name and contract address of the authorised representative whose mandate covers the tasks specified in article 12 2 Not applicable 6 System or systems of assessment and verificat...

Page 22: ...4 7 4 9 5 16 5 18 Tolerance to supply parameters Pass 5 5 Performance under fire conditions Pass 4 2 Duration of operational reliability Pass 5 11 5 12 temperature resistance Duration of operational reliability Pass 5 15 vibration resistance Duration of operational reliability Pass 5 13 5 14 humidity resistance Duration of operational reliability Pass 5 17 corrosion resistance 10 The performance o...

Page 23: ...or a particular purpose and all implied warranties arising from a course of dealing usage of trade by statute or otherwise is hereby strictly limited to the term of this written warranty This agreement shall be the sole and exclusive remedy available to the Purchaser with respect to the purchase In the event of any alleged breach of any warranty or any legal action brought by the purchaser based o...

Page 24: ... carefully checked and are reliable By the way EDS company is not responsable in any way for possible inaccurancies or errors and it reserves the right to perform changes in any part of this document and or product to improve the quality reliability or the design date 10 07 2019 sw rev R V1 3 filename RK100R_S_ist_en_2019_BLP Copyright 2005 2014 Electronic Detection Systems All rights reserved ...

Reviews: