SPM-010 Sump Pump Monitor and Control Unit
EDSPN: 2052102004
© Copyright 2022 Electronic Design Service, LLC All Rights Reserved
Page 12
Installation and Adjustment
Note: In case default calibration data does not match the actual depth of the sump, the WS-010 Water
level sensor needs to be calibrated in accordance with procedure described in WS-010 Sensor
Calibration Instruction.
WS Sensor Installation
Wire Sensor can be installed by two ways. First way, it can be attached to sump pump discharge pipe. It
allows to avoid WS-010 floating and blocking pump sensor. See Figure 5 for this connection method.
The WS-010 is installed vertically on the PVC discharge pipe of the sump pump. The sensor wire attaches
to the PVC pipe with zip ties. Place the sealed end of the sensor wire as far down the discharge pipe as
possible. Care must be taken to secure the sensor wire to the discharge pipe to avoid it being sucked
into the pump. Don’t allow the sensor wire to come in contact with the power cable of the sump pump
or metal piping as this can result in measurement inaccuracy.
NOTE: DO NOT CUT OR INCREASE WIRE SENSOR LENGTH!!!!!