ADJUSTMENTS
The HT500 Head assembly can be adjusted into varying positions to suit the operator.
While Tool is in the Pod, push handle
down and twist handle until it locks
into 1 of it's 4 positions. Twisting
counter-clockwise will permit a 180
0
turn. Twisting clockwise will permit
a 90
0
turn.
Note: Head Assembly does not make a full 360
0
turn
To tilt the Head assembly, loosen (2)
Adjustment Screws. Tilt the Head assem-
bly to desired position. Retighten
Screws.
adjustment
screws
Air out
Vacuum
Air out
Vacuum
AIR FLOW DIRECTION
Hoses must be clean and not
kinked or cracked
For Factory repair:
Specify the problem and ship the
unit to
EDSYN INC.
Customer Service
15958 Arminta Street
Van Nuys, CA 91406-1896
NOTE: When Tip orice is blocked,
use a correct size Cleaning Shaft
while pressing the Trigger to clear the
obstruction.
CS468 is .05 in. dia.
CS468-1 is .025 in. dia.
OPERATION
1. Connect HT500 to 24V power supply and vacuum source.
2. Press trigger to activate vacuum
.
3. Always clean the Tip with wet sponge and
always re-tin (add fresh solder) during and after each
operation.
Page 5