Maintenance
NRD317880 Issue A
5
Maintenance
5.1
General
Note:
The unit is easily movable on its casters.
The Acoustic Enclosure requires no regular maintenance if the indicated temperature is within the guidelines.
For the RV EM pumps regular checks can be carried out.
Figure 9 - Removing front panel to view sight glass
Figure 10 - Removing panel to gain access to filler cap
To check the oil level, remove the front end panel (lift and pull towards you). The sight glass is visible
through the opening in the covers - refer to
Figure 9
.
If the oil level needs to be topped up, remove the panel to gain access to the filler cap - refer to
Figure 10
.
CAUTION