INSTALLATION
A505-71-880 Issue C
3
INSTALLATION
3.1
Safety
z
A suitably trained and supervised technician must install the Silencer.
z
Ensure that the installation technician is familiar with and complies with the safety procedures which relate
to the products processed by the pumping system. Wear the appropriate safety-clothing when you come into
contact with contaminated components. Dismantle and clean contaminated components inside a fume-
cupboard.
z
If the GV pump has been in operation, vent and purge the process system, then shut down the GV pump and
allow it to cool to a safe temperature before you start installation.
z
Disconnect the GV pump and the other components in the process system from the electrical supply so that
they cannot be operated accidentally.
z
Use suitable lifting equipment to move the Silencer.
3.2
Unpack and inspect
Remove all packing materials and protective coverings and inspect the Silencer. If the Silencer is damaged, notify
your supplier and the carrier in writing within three days; state the Item Number of the Silencer, together with your
order number and the supplier’s invoice number. Retain all packing materials for inspection. Do not install and use
the Silencer if it is damaged.
Check that you have received the items listed in
. If any item is missing, notify your supplier in writing within
three days. If the Silencer is not to be used immediately, store it in suitable conditions, as described in
.
WARNING
Obey the safety instructions given below and take note of appropriate precautions. If you do not,
you can cause injury to people and damage to equipment.
Table 1 - Checklist of items
Qty Description
Check
(
√
)
1 Exhaust
Silencer
□
8
M8 bolts, nuts, plain and spring washers
□
1
ISO63 trapped ‘O’ ring
□