A541-11-880 Issue A
Page 8
© Edwards Limited 2010. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
Table 6 - Electrical ratings: full load conditions
Electrical sub-system: continuous / 100% full load ratings
*
*
The electrical sub-system ratings, detailed in
, assume an input short-circuit rating of 30 kA.
Input supply
voltage
Input supply
frequency
Input supply current
Input supply
power
Displayed power / motor
power
†
†
The displayed power consumption, in
, does
NOT
include the power consumption of the pump’s
internal auxiliary power-supply. This auxiliary power-supply is used to power the pump’s motor-controller,
pump-controller and customer accessories.
(V) (a.c., rms)
(Hz)
(A) (a.c., rms)
(A)
(Repetitive
Peak)
(kW)
(kW)
200
50
9.5
36.2
1.65
1.53
200
60
10.4
38.9
1.65
1.53
240
50
9.3
35.8
1.65
1.53
240
60
9.0
33.7
1.65
1.53
380
50
5.8
22.5
1.65
1.53
380
60
5.7
21.5
1.65
1.53
460
50
4.8
18.8
1.65
1.53
460
60
4.8
18.1
1.65
1.53
Table 7 - Electrical ratings: over-load condition (175% full load for 60s)
Electrical sub-system: over-load ratings
*
*
The electrical sub-system ratings, detailed in
, assume an input short-circuit rating of 30 kA.
Input supply
voltage
Input supply
frequency
Input supply current
Input supply
power
Displayed power / motor power
†
†
The Displayed Power consumption, in
, does
NOT
include the power consumption of the pump’s
internal auxiliary power-supply. This auxiliary power-supply is used to power the pump’s motor-controller,
pump-controller and customer accessories.
(V) (a.c., rms)
(Hz)
(A) (a.c., rms)
(A)
(Repetitive
peak)
(kW)
(kW)
200
50
15.1
52.9
2.85
2.62
200
60
15.3
54.1
2.85
2.62
240
50
13.4
49.2
2.85
2.62
240
60
14.5
52.8
2.85
2.62
380
50
9.9
36.6
2.85
2.62
380
60
9.6
34.6
2.85
2.62
460
50
8.2
30.2
2.85
2.62
460
60
8.0
28.9
2.85
2.62