EA 946 MODULATION GUARD VERSION 2.10; INSTRUCTIONS FOR USE
EELA AUDIO Parmentierweg 3 5657 EH EINDHOVEN THE NETHERLANDS
Page 13
The
EA946
returns to its normal monitoring mode if the studio signal returns (or the
external error input is not active) before the "ActionTime" has past, the flashing LED
"AUDIO ERROR" (and/or LED "EXT ERROR") will go out; the buzzing will also stop.
If the
EA946
has to return to its normal monitoring mode after the "ActionTime" has
past this can only be done by determining what has caused the unit to become active
(no audio or external, indicated by LED's), first take away this cause (LED's go out) and
RESET the unit by pressing the "RESET" button on the front panel of the unit or by
means of the reset possibility over the telephone line.
The external control input can also be used to disable the guard function of the unit. By
applying a voltage on this optoisolator input the unit interrupts its function e.g. by a clock
to monitor only certain airtime. For this application of the control input the function of
this input has to be set to “Inhibit Unit” in the configuration programme.