EX07200-121 Rev A
Manufacturer’s National Service Department | 400 Captain Neville Dr. Waterbury, CT 06705
Eemax® 800-543-6163 | EcoSmart® 877-474-6473 | Rheem® or Richmond® 800-374-8806
Information contained in this document is subject to change without notice.
9
Congratulations!
Your Eemax tankless electric water heater is installed and ready for use!
For temperature rise at specified flow rate, please consult the table below:
BASE MODEL*
FLOW RATE, GPM (LPM)
LavAdvantage
AccuMix II
0.35
(1.33)
0.5
(1.89)
1
(3.79)
1.5
(5.68)
2
(7.58)
2.5
(9.48)
3
(11.37)
TEMPERATURE RISE, °F (°C)
SPEX1812T
-
35
(19)
25
(14)
12
(7)
8
(4)
6
(3)
5
(3)
4
(2)
SPEX2412T
-
47
(26)
33
(18)
16
(9)
11
(6)
8
(4)
7
(4)
5
(3)
SPEX3012T
-
59
(33)
41
(23)
20
(11)
14
(8)
10
(6)
8
(4)
7
(4)
SPEX3512T
AM004120T
68
(38)
48
(27)
24
(13)
16
(9)
12
(7)
10
(6)
8
(4)
SPEX35T
-
68
(38)
48
(27)
24
(13)
16
(9)
12
(7)
10
(6)
8
(4)
SPEX48T
AM005240T
94**
(52)
66
(37)
33
(18)
22
(12)
16
(9)
13
(7)
11
(6)
SPEX55T
-
107**
(59)
75
(42)
38
(21)
25
(14)
19
(11)
15
(8)
13
(7)
SPEX65T
AM007240T
127**
(71)
89
(49)
44
(24)
30
(17)
22
(12)
18
(10)
15
(8)
SPEX75T
-
146**
(81)
102** (57)
51
(28)
34
(19)
26
(14)
20
(11)
17
(9)
SPEX95T
AM010240T
185**
(103)
130** (72)
65
(36)
43
(24)
32
(18)
26
(14)
22
(12)
SPEX012240T
AM012240T
224**
(124)
157** (87)
79
(44)
52
(29)
39
(22)
31
(17)
26
(14)
SPEX3208T
-
59
(33)
41
(23)
20
(11)
14
(8)
10
(6)
8
(4)
7
(4)
SPEX4208T
-
80
(44)
56
(31)
28
(16)
19
(11)
14
(8)
11
(6)
9
(5)
SPEX8208T
-
162**
(90)
113** (63)
57
(32)
38
(21)
28
(16)
23
(13)
19
(11)
SPEX3277T
-
59
(33)
41
(23)
20
(11)
14
(8)
10
(6)
8
(4)
7
(4)
SPEX4277T
AM004277T
78
(43)
56
(31)
28
(16)
19
(11)
14
(8)
11
(6)
9
(5)
SPEX60T
-
117**
(65)
82
(46)
41
(23)
27
(15)
20
(11)
16
(9)
14
(8)
SPEX80T
AM008277T
156**
(87)
109** (61)
55
(31)
36
(20)
27
(15)
22
(12)
18
(10)
SPEX90T
-
176**
(98)
123** (68)
61
(34)
41
(23)
31
(17)
25
(14)
20
(11)
SPEX100T
AM010277T
195**
(108)
137** (76)
68
(38)
46
(26)
34
(19)
27
(15)
23
(13)
**Note: the heaters’ actual temperature rises are limited by their thermostatic controls (max 90°F, max 110°F, max 140°F, max 180°F, based on
model suffix). The theoretical values shown above are only for comparison purposes.
After the 60 seconds in step 4, the display will show the temperature setpoint. See
The heater is commissioned at this point. Faucet can be turned off and used as
needed.
Note: the temperature display will turn off after 5 minutes of inactivity. Display turns
on when water flows through heater.
FLOWCO
The InfoCue™ will flash rapidly while water flows through the unit. Maintain flow.
After 15 seconds, the InfoCue will turn solid red and there will be an audible click.
The heater is commissioned at this point. The faucet can be turned off and used as
needed.
Note: with no flow, the unit will flash every 4 seconds, indicating normal stand-by
mode.