3) ELECTRICAL HOOK-UP
This heater must have its own independent circuit using insulated, UL listed, 2 wire cable (2 wire plus ground) of
the appropriate size suitable for up to 75°C and protected by the correctly rated circuit breaker. For
recommended copper wiring for conductors with a temperature rating of 75°C refer to the chart below:
ELECTRICAL SPECIFICATIONS
BEFORE BEGINNING ANY WORK ON THIS INSTALLATION, BE SURE THAT THE
ELECTRICAL BREAKER IS “OFF” AND THAT ALL MOUNTING AND PLUMBING WORK HAS
BEEN COMPLETED PER THESE INSTRUCTIONS.
AccuMix II model number
Voltage
(VAC)
Max power
(kW)
Max current
(A)
Minimum wire size
(AWG) @75°C rating
AM004120T
120
3.5
29
10
AM005240T
240
4.8
20
14
AM007240T
240
6.5
27
10
AM010240T
240
9.5
40
8
AM012240T
240
11.5
48
8
AM004277T
277
4.1
15
14
AM008277T
277
8.0
29
10
AM010277T
277
10.0
36
8
1.
Power cable entry to the heater should be made
through one of the knock-out holes located on the
back plate or top/bottom ends of the unit. Use the
appropriate strain relief fitting.