4- PLUMBING INSTALLATION 

 

Please follow all plumbing instructions carefully. We recommend that this product be installed by a licensed 
and qualified plumber in accordance with all applicable national, state, provincial, and local plumbing codes.  

 

Installation Instructions 

 
STEP 1: 

Connect the HOT WATER line to the water heater marked HOT WATER OUTLET located on the left side of the 

heater when facing unit. Connect the COLD WATER line to the water heater marked COLD WATER INLET on the right 
side when facing unit. 

 

STEP 2: 

After tightening both fittings at the water heater, open several hot water faucet s and allow water to 

run though the water heater for at least 2 to 3 minutes. This process purges all the air from the water lines  and 
MUST be performed prior to turning on the power at the unit. FAILURE TO FOLLOW THIS STEP CAN CAUSE 
PERMANENT DAMAGE TO THE HEATING ELEMENTS. If any maintenance is performed on the water heater or 
the home’s plumbing system that may introduce air into the plumbing pipes, it is important to turn the power off 
to the water heater and purge the air out of the lines before allowing the unit to power up. 

STEP 3: 

Carefully inspect all connections, unions, and the pressure relief valve (if installed) for leaks. 

 

 IMPORTANT NOTES: 

1.

 

Do not solder any pipes with unit connected to pipes – heat from soldering may damage the flow 
sensor. Doing so will also void the warranty.  
 

2.

 

This Eemax tankless water heater is equipped with both computer-controlled and electro-mechanical auto 
resetting thermostat switches for high-limited temperature protection. Since this product does not use a 
storage tank, the use of a temperature pressure relief valve (T&P) is not required for most installations. 
UL Standard 499 does NOT require that a pressure relief valve be used. However, a T&P valve may be 
required to meet installation codes in your area. If one is required, install the pressure relief valve in 
accordance with local codes and ensure that it operates correctly and that air is purged from the valve 
prior to installing the water heater. When connecting to Flex or High Temperature CPVC pipe, we 
recommend that a T&P valve be used for added safety.  

Please note: Installations in the Commonwealths of Massachusetts and State of Kentucky require a 
pressure relief valve. Please check your local installation codes for any special requirements.  

 

3.

 

The maximum operating water pressure is 150 PSI. If the water pressure is higher, a pressure reducing 
valve must be installed on the main incoming water supply line prior to installing the electric tankless 
water heater. 

 

4.

 

Flexible water heater hoses can and are recommended to be used with your water heater as part of 
the installation. When connecting the inlet water pipe to the unit, make sure  to use a wrench to 
hold the units connection, and another wrench to tighten, so the flow sensor on the unit is not 
loosened or damaged. Serious internal damage to the water heater can occur if the inlet or 
outlet connections are over tightened or if solder c onnections were made.  
 

5.

 

We recommend that a manual shut-off valve (ball valve) be installed on the inlet and outlet of the 
water heater so there is a convenient shut-off point available in the event that future maintenance 
or servicing is required. Before connecting pipes to the water heater, it is extremely important to 
flush the lines to eliminate all plumbing paste or residue in the lines caused by any welding or soldering.  
 
 

We recommend that all the water pipes or hoses within 3 feet of the inlet and outlet connections be rated for 
high temperature applications with a 150°F minimum.

  

 

Summary of Contents for EEM24008

Page 1: ...ly at the breaker box SERIOUS BODILY INJURY OR DEATH COULD OCCUR IF YOU IGNORE THIS WARNING THIS PRODUCT SHOULD BE INSTALLED BY A QUALIFIED ELECTRICIAN OR PLUMBER IN ACCORDANCE WITH ALL NATIONAL STATE PROVINCIAL AND LOCAL ELECTRICAL PLUMBING CODES PLEASE READ THESE INSTRUCTIONS THOROUGHLY AND COMPLETELY PRIOR TO INSTALLATION USE FAILURE TO DO SO COULD CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH ...

Page 2: ......

Page 3: ...ve any questions please contact us directly at EemaxInc 400CaptainNevilleDrive Waterbury CT06705 Toll Free 1 800 543 6163 or 203 267 7890 Fax 203 267 7975 info eemaxinc com CONTENTS 1 BEFORE INSTALLATION 2 SELECTING A LOCATION TO INSTALL 3 MOUNTING YOUR WATER HEATER 4 PLUMBING INSTALLATION 5 ELECTRICAL INSTALLATION 6 SIZING GUIDE 7 GENERAL OPERATING INSTRUCTIONS 8 MAINTENANCE 9 TROUBLE SHOOTING GU...

Page 4: ...electrical boxes or junctions If you plan to install your water heater on a second floor or in a heated attic space make sure that you follow all code requirements for such installations as required for your area We recommend that you install a drip pan connected to a safe drain below the water heater to avoid property damage in the unlikely event of a leak Alternatively you can install an active ...

Page 5: ...ons UL Standard 499 does NOT require that a pressure relief valve be used However a T P valve may be required to meet installation codes in your area If one is required install the pressure relief valve in accordance with local codes and ensure that it operates correctly and that air is purged from the valve prior to installing the water heater When connecting to Flex or High Temperature CPVC pipe...

Page 6: ...odelEEM24024and EEM24027 require 3 sets of wires and ground seewiringdiagram ModelEEM24036 requires4 sets of wires and ground seewiringdiagram Pleaseseerequiredwiregaugeonthenext page Eachsetof wiresmust beconnectedtoitsownindividualdoublepolebreaker InstallationInstructions STEP1 Takeeachwirepairandconnectthemtoonebreaker seewiringdiagram Makesurethateachbreakeris connectedwithoneblackwireandone ...

Page 7: ...REQUIRED BREAKERS 1 x 40 AMP 1 x 50 AMP 1 X 60 AMP 2 X 40 AMP 3 x 40 AMP 3 X 40 AMP 4 X 40 AMP REQUIRED WIRE GAUGE 1 x 8 AWG 1 X 6 AWG 1 X 6 AWG 2 X 8 AWG 3 x 8 AWG 3 X 8 AWG 4 X 8 AWG Circuit Breaker 1 L1 L1 EEM24018 requires 2 sets of breakers and wires EEM24024 EEM24027 require 3 sets of breakers and wires EEM24036 requires 4 sets of breakers and wires EEM24008 EEM24011 EEM24013 require 1 set o...

Page 8: ...t of your unit to a specified flow rate to prevent theexit temperature from becoming too cool To learn moreabout flow restrictors or find out how to purchase one for your tankless water heater visit us online at Eemax com or contact us at 1 800 543 6163 Steps for Choosing a Flow Restrictor 1 Find your modelin the chart on the left 2 Choose the column with the inlet water temperature closestto your...

Page 9: ...reduce the risk of a water leak we recommend the following maintenance You should inspect the connections on the inlet and outlet of the water heater at least on an annual basis for any signs of damage or failure Any signs of damage cracks leakage or weakness should be address Take care not to over tighten the connections Serious internal damage to your water heater can occur if you over tighten t...

Page 10: ...ossible that the wiring is incorrect Voltage less than 240 volts The heating elements on your water heater are design for 240 volts When use with a lower voltage they produce less heating power You may need to upgrade to a larger model Mixing too much cold water You do not need to mix as much cold water with your tankless water heater compared to when you use a conventional water heater You may al...

Page 11: ...the cover to change the temperature set point exposes electrical shock and burn hazards which can cause INJURY or DEATH Adjustment should only be done by a licensed plumber or electrician EEM24008 EEM24011 EEM24013 EEM24018 EEM24024 EEM24027 EEM24036 1 Hot Water Outlet 5 Adjustment Stem Temperature Control 9 Electrical Conduit 2 Cold Water Inlet 6 Wire Connection 10 Mounting Bracket 1 3 Celsius Fa...