“T2” MODELS
a) Switch on the power to the first unit, the power indicator light should illuminate.
Note: This light should pulse On and Off at first and after about 20- 30 seconds it should
stay fully on.
b) Switch on the power to the second unit, again the power indicator light should illuminate.
Note: This light should pulse On and Off at first and after about 20- 30 seconds it should
stay fully on.
c) Use the OUTLET ball valve to gradually reduce the water flow until the power indicator lights
on both units begin to pulsate. The water temperature should now be approximately
140° F.
For “T” and “T2”, TC Models
If a lower temperature is required, turn the temperature adjustment screw(s) counter-clockwise
about 1/8 of a turn (See Figure 1). Wait 15-20 seconds and check the temperature at the fixture.
Repeat this process until the desired temperature has been achieved. (For T2 & TC models try to
adjust both temperature adjustment screws by about the same amount so that the lights pulse at the
same rate.) If you have reduced the temperature considerably from the 140° F setting, you could now
open up the outlet ball valve slightly to achieve a higher rate of flow.
When the indicator light is on continuously, the unit is emitting full power. When it is pulsing, the
unit is modulating the power to achieve the temperature set by means of the temperature
adjustment screw.
ALL HEATERS
In order to obtain good control at “single lever” mixer type faucets (single spout) the cold water
supply to the faucet should be restricted to give approximately the same flow rate of cold water
to the faucet as the hot water coming from your Eemax heater. The simplest method of doing
this is by partially closing the cold water valve under the sink.
MAXIMUM TEMPERATURE RISE CHART (
0
F )
FLOW RATE ( GAL. PER MIN. )
OUTPUT
0.75
1 1.25
1.5
2
2.5
3
15 kW
N/A
102
82
68
51
40
34
16 kW
N/A
109
87
73
55
44
36
19 kW
N/A
130
104
87
65
52
43
20 kW
N/A
136
109
91
68
54
45
8